Sartorius Group - LMA200PM-000US

Manufactured by  Sartorius Group
Follow this Equipment

If the sample contains a high moisture content, microwave drying is the fastest and most effective procedure...

If the sample contains a high moisture content, microwave drying is the fastest and most effective procedure (loss-on-drying) for heating samples. A sample is heated by absorption of microwave radiation. A built-in analytical weighing system measures the weight loss of a sample and determines the end point at which the sample has reached a constant weight. In addition, an air moisture sensor monitors the progress of a moisture analysis run, thus providing double the certainty to assure reliable results.
Active Questions & AnswersAsk a Question

There are no current Discussions

Moisture Analyzers Service ProvidersView All (3)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of LMA200PM-000US
  • Can be used for liquid and pasty samples with a moisture content ranging from approx. 8 to 100%
  • Analysis time approx. 40 - 120 seconds (depends on type of sample and moisture content)
  • Easy two-key operation for routine moisture measurements
  • End-point determination: Fully automatic, by means of mass and moisture sensors; User-defined as loss of weight/unit of time for measurement; Timer mode
  • Built-in analytical weighing system with a capacity of 70 g and a resolution of 0.1 mg for weight values
General Specifications

There are no General Specifications available.

Additional Specifications

[u]Product properties[/u] 
Heating source  
Microwave radiation, for ultra short measuring times 
Application  
Very moist samples, fluid or pasty 
Recommended moisture range  
8 - 100% 
Weighing capacity  
70 g 
 
[u]Technical attributes[/u] 
Accuracy of the weighing system  
0,0001g 
Reproducibility (Repeatability) on average for initial sample weights of 1 g or higher (%) 
+/- 0.05 
Type of sample carrier  
Glass fiber pads, diameter 90mm (3.5") 
Display mode for results  
% moisture, ppm moisture, % volatile components, % dry weight (solids), ppm dry weight, g dry weight, mg weight loss, % RATIO 
Temperature range and settings  
Approx. 8 - 100 % moisture 
End-point determination  
Fully automatic, by means of mass and moisture sensors; User-defined as loss of weight/unit of time: 1-50 mg / 1-99 sec., 0.1-9.9% / 1-99 sec.; Timer mode: 0.1 - 99.9 min. 
Analysis time  
Approx. 40-120 (depends on type of sample and moisture content) 
Data Printer  
Thermal printer, built-in 
Moisture measurement report  
User-configured GLP report: The report can be printed on non-fading paper by the built-in thermal printer 
Data interface  
1x RS232 port for PC; 1x Ethernet port 
Line frequency  
50 Hertz 
Width  
20 x 21 x 12 inch 
Max. power consumption  
1200 VA