Sartorius Group - LMA200PM-000US

Manufactured by  Sartorius Group
Follow this Equipment

If the sample contains a high moisture content, microwave drying is the fastest and most effective procedure...

If the sample contains a high moisture content, microwave drying is the fastest and most effective procedure (loss-on-drying) for heating samples. A sample is heated by absorption of microwave radiation. A built-in analytical weighing system measures the weight loss of a sample and determines the end point at which the sample has reached a constant weight. In addition, an air moisture sensor monitors the progress of a moisture analysis run, thus providing double the certainty to assure reliable results.
Active Questions & AnswersAsk a Question

There are no current Discussions

Moisture Analyzers Service ProvidersView All (3)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of LMA200PM-000US
  • Can be used for liquid and pasty samples with a moisture content ranging from approx. 8 to 100%
  • Analysis time approx. 40 - 120 seconds (depends on type of sample and moisture content)
  • Easy two-key operation for routine moisture measurements
  • End-point determination: Fully automatic, by means of mass and moisture sensors; User-defined as loss of weight/unit of time for measurement; Timer mode
  • Built-in analytical weighing system with a capacity of 70 g and a resolution of 0.1 mg for weight values
General Specifications

There are no General Specifications available.

Additional Specifications

Product properties 
Heating source  
Microwave radiation, for ultra short measuring times 
Application  
Very moist samples, fluid or pasty 
Recommended moisture range  
8 - 100% 
Weighing capacity  
70 g 
 
Technical attributes 
Accuracy of the weighing system  
0,0001g 
Reproducibility (Repeatability) on average for initial sample weights of 1 g or higher (%) 
+/- 0.05 
Type of sample carrier  
Glass fiber pads, diameter 90mm (3.5") 
Display mode for results  
% moisture, ppm moisture, % volatile components, % dry weight (solids), ppm dry weight, g dry weight, mg weight loss, % RATIO 
Temperature range and settings  
Approx. 8 - 100 % moisture 
End-point determination  
Fully automatic, by means of mass and moisture sensors; User-defined as loss of weight/unit of time: 1-50 mg / 1-99 sec., 0.1-9.9% / 1-99 sec.; Timer mode: 0.1 - 99.9 min. 
Analysis time  
Approx. 40-120 (depends on type of sample and moisture content) 
Data Printer  
Thermal printer, built-in 
Moisture measurement report  
User-configured GLP report: The report can be printed on non-fading paper by the built-in thermal printer 
Data interface  
1x RS232 port for PC; 1x Ethernet port 
Line frequency  
50 Hertz 
Width  
20 x 21 x 12 inch 
Max. power consumption  
1200 VA