ATAS GL - Multi Mode Inlet OPTIC 3

Manufactured by  ATAS GL
Follow this Equipment

The OPTIC 3 is the world most universal Multi Mode Inlet system for Gas Chromatography. (MMI)

Increase capacity of your GC system with OPTIC 3 injector!

OPTIC 3 is a highly advanced injector with sophisticated temperature and gas flow control that can be used for the most demanding GC analyses. As its predecessor, OPTIC 2, the new system can be used for hot split/splitless, cold split/splitless and on-column injections. Standard available facilities are:

  1. Large Volume Injections
  2. Thermal Desorption
  3. Pyrolysis (liquid and solid)
  4. Cryo Focus


OPTIC 3 is designed to be compatible with most popular makes and models of GC and GC-MS. Once installed, OPTIC 3 should be fully compatible with an autosampler.

OPTIC 3 system consists of the injector, the control unit and the dedicated control software - ATAS Evolution Workstation. There is also a special solvent sensor in the split line, this sensor can be used for automatic solvent venting. The software graphically displays all the system parameters in a real time mode and gives a possibility to save the run-time data for every injection.

The patented design of the injector body helps to have the best transfer of the compounds from the injector onto the analytical column. This can be seen both for volatile and heave compounds.
Active Questions & AnswersAsk a Question

There are no current Discussions

GC Components Service ProvidersView All (1)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of Multi Mode Inlet OPTIC 3
  • Large, up to 100 µl at-once volume sampling
  • Cold as well as hot split/splitless injections
  • Direct (in-injector) thermal desorption for any type of sample
  • Difficult Matrix Introduction (DMI) - handling large volumes of dirty sample extracts with non-volatile matrix
  • Optional automated liner exchange
  • Optional integrated cryogenic trap control
  • Discrimination free to C100
  • Pyrolysis up 600 °C with ramp rate up to 30 °C/sec
  • Compatible with most GC’s and autosamplers
General Specifications

There are no General Specifications available.

Additional Specifications

General:
Dimensions: 43cm x 15cm x 43cm (H x W x D)
Weight: 11 kg
Ambient temperature range: 10 - 40ºC
Ambient operating humidity: 5 - 90%
Mains power: 100-240 V AC, 50/60 Hz
Power consumption: 80 VA
Conforms to safety standards:
The European Low Voltage Directive 73/23/EEC
The Electromagnetic Compatibility Directive 89/336/EEC
Storage of ten methods and three sequences

Injector:
Full electronic pressure/flow control
Maximum operating temperature: up to 600ºC at a GC oven temperature of 35ºC
Cooling: air (down to 35ºC), LCO2 (down to -50ºC), LN2 (down to -180ºC)
Temperature ramp rates: 1 - 30ºC/sec, in 0.1ºC increments
Up to nine temperature programme ramps including negative
Compatible with Merlin Micro Seal septum
Compressed air for cooling: moisture and oil free air at a pressure of 500 kPa (80 PSI)

Electronic Gas Control:
Two EGC channels
Full electronic control of column, split and septum purge flows
Pressure range: 2 - 100 psi
Flow range: 6 - 300 ml/min He (main channel, all models), 6 - 100 ml/min He (auxiliary channel, OPTIC 3-D and DC only)

Pressure sensors:


  1. accuracy : ±2% full scale
  2. repeatability: ±0.2% full scale


Flow sensors:
  • accuracy : ±2% full scale
  • repeatability: ±0.2% of full scale
    Up to nine flow/pressure programme ramps
    He, N2 or H2 carrier gas at a maximum pressure of 100 psi (700 kPa)
    Solvent detector (TCD) in the split line

    External Communication:
    LAN
    RS-232 (115,200 baud max.)
    Seven auxiliary relay outputs (30V/500 mA max.)
    External 5 V and 24 V supply connections (250 mA max.)
    Remote start/stop to GC and auto sampler
    Four auxiliary inputs