PFEIFFER VACUUM - Air Cooled CV versions
Manufactured by PFEIFFER VACUUM
Dry Compact Multi-stage Roots Pumps. Clean Vacuum. High Reliability.
CV versions extend the pure water vapor capacity up to 1,000 g/h (at 100 mbar and 30 °C ambient temperature). A high gas ballast flow warms up the pump and dilutes condensable gases (> 2 N.m3/h or 33 slm at 1 bar abs.). The external drainable silencer recovers liquid from the lowest point of the exhaust stage. A gas purge line injection device helps to protect lips seals and ball bearings from condensable vapors.
Customer value
Air cooling: no water supply required
Frequency inverter: hour meter, remote operation mode (RS-485, dry contacts, Profibus on request), multiple rotational speed selection (power saving, noise reduction, adaptation to application cycle)
Universal power supply: wide voltage range 50/60 Hz, single-phase and three-phase
Standards: compliance with CE standards, UL/CSA certified, SEMI S2 certified
Customer value
Active Questions & AnswersAsk a Question
There are no current Discussions
Vacuum Pumps Service ProvidersView All (13)
Documents & ManualsView All Documents
Features of Air Cooled CV versions
[u]ACP 28 CV: Product description[/u]
Dry multi-stage Roots technology, CV versions, ACP pumps with a pumping speed of max. 28 m3/h
No particle contamination, thanks to frictionless design: no wearing parts in the pumped gases path
No hydrocarbon vapors backstreaming: ACP series pumps are free of lubricant inside the pumping module
Constant performances (Pumping speed, max. and ultimate pressure)
High reliability: thanks to our expertise of dry multi-stage Roots pumps since 1988
Low maintenance costs: no annual field service, complete overhaul only every 22,000 hours for ACP 28/40
Condensable vapor ability: with gas ballast ports and drainable silencer. ACP series pumps can handle up to 1,000 g/h of pure water vapor.
Options:
ACP 28, CV version, single-phase, permanent gas ballast (V6GVTSFEHF)
ACP 28, CV version, single-phase, manual gas ballast (V6GVTSFEVF)
ACP 28, CV version, three-phase, permanent gas ballast (V6GVTSTRHF)
ACP 28, CV version, three-phase, manual gas ballast (V6GVTSTRVF)
[u]ACP 40 CV: Product description[/u]
Dry multi-stage Roots technology, CV versions, ACP pumps with a pumping speed of max. 40 m3/h
No particle contamination, thanks to frictionless design: no wearing parts in the pumped gases path
No hydrocarbon vapors backstreaming: ACP series pumps are free of lubricant inside the pumping module
Constant performances (Pumping speed, max. and ultimate pressure)
High reliability: thanks to our expertise of dry multi-stage Roots pumps since 1988
Low maintenance costs: no annual field service, complete overhaul only every 22,000 hours for ACP 28/40.
Condensable vapor ability: with gas ballast ports and drainable silencer. ACP series pumps can handle up to 1,000 g/h of pure water vapor.
Options:
ACP 40, CV version, single-phase, permanent gas ballast (V8GVCSFEHF)
ACP 40, CV version, single-phase, manual gas ballast (V8GVCSFEVF)
ACP 40, CV version, three-phase, permanent gas ballast (V8GVCSTRHF)
ACP 40, CV version, three-phase, manual gas ballast (V8GVCSTRVF)
General Specifications
There are no General Specifications available.