PFEIFFER VACUUM - HiQuad™ QMG 700

Manufactured by  PFEIFFER VACUUM
Follow this Equipment

Gas analysis in the pressure range up to 10-4 hPa.  Quantitative analysis of gas compositions. Pfeiffer Vacuum...

Gas analysis in the pressure range up to 10-4 hPa.   
Quantitative analysis of gas compositions. Pfeiffer Vacuum high end mass spectrometers help you to determine concentrations of gases in gas mixtures.
Active Questions & AnswersAsk a Question

There are no current Discussions

Vacuum Pumps Service ProvidersView All (13)

Request Support
Features of HiQuad™ QMG 700
[u]HiQuad™, QMG 700, with QMA 410, 16 mm molybdenum rod system[/u]    HiQuad mass spectrometer system with user-friendly Quadera software. Comes with HiQuad control unit, HF generator and QMA 410 analyzer with 16 mm molybdenum rod system and 90° off-axis secondary electron multiplier (SEM). Available for 1-128 amu and 1-340 amu mass ranges. The system with the lowest suitable mass range for the application in question should be chosen.        Product description   
  • Maximum sensitivity and broad dynamic range   
  • Outstanding long-term stability   
  • Extremely high measuring speed   
  • Optimum resolution, mass separation and transmission        Product Options    HiQuad™, QMG 700 with QMA 410, 1-128 amu    HiQuad™, QMG 700 with QMA 410, 1-340 amu                [u]HiQuad™, QMG 700, with QMA 430, 8 mm stainless steel rod system[/u]    HiQuad mass spectrometer system with user-friendly Quadera software. Comes with HiQuad control unit, HF generator and QMA 430 analyzer with 8 mm stainless steel rod system and 90° off-axis secondary electron multiplier (SEM).        Product description   
  • Maximum sensitivity and broad dynamic range   
  • Outstanding long-term stability   
  • Extremely fast measuring speed        Product Options    HiQuad™, 1-300 amu            [u]HiQuad™, QMG 700, with QMA 400, 8 mm molybdenum rod system[/u]    HiQuad mass spectrometer system with user-friendly Quadera software. Comes with HiQuad control unit, HF generator and QMA 400 analyzer with 8 mm molybdenum rod system and 90° off-axis secondary electron multiplier (SEM). Available for 1-512 amu, 1-1025 amu and 1-2048 amu mass ranges. The system with the lowest suitable mass range for the application in question should be chosen.        Product description    High sensitivity and broad dynamic range    Outstanding long-term stability    Extremely fast measuring speed    High resolution, mass separation and transmission        Product Options    HiQuad™, QMG 700, 1-1024 amu    HiQuad™, QMG 700, 1-2048 amu    HiQuad™, QMG 700, 1-512 amu
  • General Specifications

    There are no General Specifications available.

    Looking for New or Used Equipment?

    Shop on LabX

    Shop on Labx.com