High performance capillary electrophoresis is based on the differential migration of components of aqueous samples within a narrow fused silica capillary driven by an electric field. Separated solutes are quantitatively detected at the capillary outlet by a high sensitive optical system based on direct or indirect UV absorbance.
ANALYTICAL CHARACTERISTICS
Detectors
CAPEL®-205 is equipped with a spectrophotometric detector with a wavelength range of 190 - 400 nm.
Light source
Deuterium lamp
Vials
Standard centrifuge-type (e.g.Eppendorf-type)1.5 ml, minimal sample volume 100 µl.
Injection modes
Sample injections by pressure, vacuum or electrokinetically.
Controlled pressure profile of injection with pressure values from – 100 mbar to + 100 mbar.
Electrokinetic injection at (+/-) 1 – 30 kV considering time for voltage ramping.
Programmable injection time / pressure / voltage.
Analysis
With a Voltage from -30 kV to +30 kV with a 1 kV step and an electronic polarity switch.
Current from 0 to 300 µA.
Elforun® software features
Combination of instrument controlling, data acquisition and data processing;
Real time electropherogram visualization;
Electropherogram data processing with overlay mode and basic mathematical operations;
Computation of electrophoresis system parameters;
Customized report output (hard copy and file), data exchanges with worksheets, databases and word processors;
Extensive data processing algorithm customization;
GLP and GALP compliance.
EQUIPMENT AND OPTIONS
Capillary electrophoresis system CAPEL®-205;
Spare capillary cassettes;
Elforun® software package;
Kits for analyses (by request); most of CE-kits of any manufacturers are compatible with Capel®-205.
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & ManualsView All Documents
Features of CE System CAPEL®-205
Extended instrumental options
Extended autosampler capacity up to 59 positions – hundreds of samples per months can be analyzed * Integrated vials caps removal – all solutions are kept in the autosampler tightly closed excluding evaporation and cross-contamination * New HV block provides voltage up to +/- 30 kV – separation efficiency is improved and analysis time is decreased * Redesigned capillary cassette – length of the thermostated part of the capillary is increased to improve migration time reproducibility * Spectra scanning facilitates peak identification * Broad range of controlled injection pressure allows analysis of viscous samples * Reverse sample injection under vacuum: ultra-short analysis time (less than 1 min) and sample stacking to decrease detection limit
Precise and highly effective capillary thermostating provided by circulating liquid coolant (water)(± 0.1 C) Extended range of applied buffers and increased efficiency in separation
Powerful software package "Elforun®" * Modified Elforun-205 to become even more user-friendly when operating with extended autosampler capacity * Increased flexibility in performing analyses of various complexity * Any kinds of complex runs are possible including those with pre-programming of changes in analysis conditions * Customized report, data export to other programs
Unique design of the capillary cassettes * Enlarged thermostatic part of the capillary improves migration time reproducibility * Easy capillary change in just a few minutes * Lower Detection Limit due to the optimized optical scheme
General Specifications
Depth | 470 cm |
Height | 530 cm |
Width | 410 cm |
Power Requirements | 110/220 Vac, 50/60 Hz |
Weight | 30 kg |
Electropheresis Type | Capillary |
Additional Specifications
Detector:
Spectrophotometer
190-400 nm
Analysis:
Constant voltage (+/-) 1 - 30 kV in 1 kV steps
Automatic (electronic) polarity switch
Current 0 - 300 mkA
Pressure (+/-) 1-100 mbar
Programmable changing of wavelength, pressure and voltage during analysis
Injection:
By voltage
By pressure
By vacuum
Sampler:
Autosamplers for 59 vials
Rinsing:
With pressure ~1000 or 2000 mbar
Capillary:
Length: 30-100 cm
Internal diameter: 50, 75, 100 Μm
Capillary thermostating:
Liquid thermostating conducted at temperatures from 10 ºC below to 30ºC above ambient temperature (± 0.1 C)
Controlled parameters:
Wavelength
Pressure
Temperature
Voltage