Lumex Instruments - FLUORAT®-02-4M/ FLUORAT®-02-5M
Manufactured by Lumex Instruments
FLUORAT-02 is a fluorescence analyzer intended for analysis of water, air, foodstuff, etc. using large number of...
FLUORAT-02 is a fluorescence analyzer intended for analysis of water, air, foodstuff, etc. using large number of fluor?metric, photometric, and chemoluminometric techniques.
The base unit FLUORAT-02-4M/5M is a filter fluorimeter, chemiluminometer and photometer combined in one optoelectronic scheme whereas the FLUORAT-02-4M version is in addition to that a time-resolving fluorimeter and can also be used as a fluorimetric detector in any HPLC (High Performance Liquid Chromatography) system.
PRINCIPLE OF OPERATION
The fluorescence (phosphorescence, or chemiluminescence) intensity measurement and measurement of sample transmittance.
The base unit FLUORAT-02-4M/5M is a filter fluorimeter, chemiluminometer and photometer combined in one optoelectronic scheme whereas the FLUORAT-02-4M version is in addition to that a time-resolving fluorimeter and can also be used as a fluorimetric detector in any HPLC (High Performance Liquid Chromatography) system.
PRINCIPLE OF OPERATION
The fluorescence (phosphorescence, or chemiluminescence) intensity measurement and measurement of sample transmittance.
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & Manuals
There are no Documents or Manuals available.
Features of FLUORAT®-02-4M/ FLUORAT®-02-5M
Low detection limit;
High analytical selectivity compared to conventional photometric devices;
Analysis of a large variety of components;
Quick analysis with low reagent consumption;
Nonvolatile memory for calibration and other analysis parameters;
?an operate as a fluor?meter, chemiluminometer, photometer, and nephelometer and can also be used as a HPLC detector (FLUORAT-02-4M);
COD-reactor TERMION can be used for Chemical Oxygen Demand measurements.
FLUORAT-02-4M and FLUORAT-02-5M analyzer versions
FLUORAT-02-4M allows measurement of the phosphorescence when operating in the time-resolving fluorimeter mode. This mode is used for instance to determine uranium and is characterized by a very high sensitivity and selectivity.
General Specifications
| Depth | 305 mm |
| Height | 110 mm |
| Width | 320 mm |
| Power Requirements | 200-240 Vac, 50 Hz, 36 W |
| Weight | 6.5 kg |
Additional Specifications
Spectral range 02-5M:
250-900 nm
Spectral range 02-4M:
250-650 nm
Detection limit (phenol):
5 Μg/L
Cell:
10, 20 and 40 mm