Features of CLA 5

Benefits at a Glance

  • Memory for 1000 tests, 20 operators, 100 sample names, 21 test methods
  • Statistical analysis (Min, Max, Mean, Repeatability)
  • Measures flash points of silicone samples without any problems
  • Automatically lights up the test flame, relights it by an electric igniter and suppresses the gas source at the end of the test

Convenient Operation

  • Test initiation by pre-installed standard test methods and ability to customize methods by 10 user-defined programs.
  • Alert messages for out-of-spec results
  • Pt100 sample temperature probe calibration either by dynamic calibration against certified ASTM thermometer or by correction table with 21 calibration points.
  • Calibration protocol printout
  • 5.7” color graphics display shows real-time measurement
  • Menu navigation by jog shuttle system with easy turn-and-push operation and color-coded LED indication for each operation mode
  • Data handling via USB stick for import into MS Excel® or to LIMS

Customized User Flexibility

  • PC-software FPPNet (optional) for convenient remote handling and test data storage
  • Automatic skin removal kit (optional)
  • Draft deflector (optional)
  • Stainless steel sample temperature probe Pt100 (optional)
General Specifications
Depth 390 mm
Height460 mm
Width 230 mm
Power Requirements 115 V/230 V, 50 Hz/60 Hz, 600 W
Weight12 kg
Additional Specifications

Application range  
up to 400 °C (°C/°F selectable) 
 
Ignition  
Gas 
 
Heating  
According to methods, programmable and pre-heat mode 
 
Detection of flash and fire point  
Ionization detector 
 
Sample temperature  
Pt100 glass probe 
 
Barometric pressure correction  
Automatic correction 
 
Safety  
Overheat protection, automatic shut-off 
 
Interfaces  
3x USB, 1x RS232, LAN 
 
Gas supply  
50 mbar of propane or butane