• Exterior Dimensions: 61.3”W x 31.3”D x 26.5”H (1557 x 795 x 673 mm)• Interior Dimensions: 42.5”W x...
• Exterior Dimensions: 61.3”W x 31.3”D x 26.5”H (1557 x 795 x 673 mm)
• Interior Dimensions: 42.5”W x 28.5”D x 25.2”H (1080 x 724 x 640 mm)
• Incubator Interior Dimensions: 36”W x 8.7”D x 8”H (915 x 221 x 203 mm)
• Airlock Interior Dimensions: 12”W x 13.5”D x 12”H (305 x 343 x 305 mm)
• Material: Stainless Steel and Plexiglass
• Interior Outlet 2 (120V): 2, 1 amp. Max; Exterior Outlet, Vacuum: 5 amps. Max
• Nominal Voltage 60HZ (V): 110-120
• Capacity: 300 plates
• Overtemperature Alarm: Yes
• Maximum Energy Consumption (W): 1100
• Airlock Volume: 1.1 cu. ft. / 31 L; Working Chamber Volume: 17.6 cu. ft. / 498 L
• Incubator Volume L: 1.4 (39.6)
• Temperature Range: 5°C above ambient to 70; Temperature Uniformity: +/- 0.5°C at 70 °C
• Petri Racks Included : 8
• Agency Approval: TUV-CUE
• Meets EN61010, UL61010 and Can/CSA61010 standards
o Includes: vacuum pump, AMG Regulator, interior electrical outlet, sleeve assembly with medium cuff, and 8 petri racks
o Operates as a one gas (Anaerobic Mixed Gas [AMG]) or two gas (AMG and nitrogen) system
o Ergonomic arm port doors simplify access and maintain a strict anaerobic environment
o Airtight construction and gloveless design with patented cuffs
o Manual or automatic airlock with sliding shelves
o User-friendly Control Panel Layout and microprocessor controls
o Automatic pressure controls provide positive pressure at approx. 3” of water column and shows pressure level
o Incubator located inside, top rear of chamber
o Available Installation and Training Workshop (for USA orders only)
o Two-Year Manufacturer Limited Warranty
• Interior Dimensions: 42.5”W x 28.5”D x 25.2”H (1080 x 724 x 640 mm)
• Incubator Interior Dimensions: 36”W x 8.7”D x 8”H (915 x 221 x 203 mm)
• Airlock Interior Dimensions: 12”W x 13.5”D x 12”H (305 x 343 x 305 mm)
• Material: Stainless Steel and Plexiglass
• Interior Outlet 2 (120V): 2, 1 amp. Max; Exterior Outlet, Vacuum: 5 amps. Max
• Nominal Voltage 60HZ (V): 110-120
• Capacity: 300 plates
• Overtemperature Alarm: Yes
• Maximum Energy Consumption (W): 1100
• Airlock Volume: 1.1 cu. ft. / 31 L; Working Chamber Volume: 17.6 cu. ft. / 498 L
• Incubator Volume L: 1.4 (39.6)
• Temperature Range: 5°C above ambient to 70; Temperature Uniformity: +/- 0.5°C at 70 °C
• Petri Racks Included : 8
• Agency Approval: TUV-CUE
• Meets EN61010, UL61010 and Can/CSA61010 standards
o Includes: vacuum pump, AMG Regulator, interior electrical outlet, sleeve assembly with medium cuff, and 8 petri racks
o Operates as a one gas (Anaerobic Mixed Gas [AMG]) or two gas (AMG and nitrogen) system
o Ergonomic arm port doors simplify access and maintain a strict anaerobic environment
o Airtight construction and gloveless design with patented cuffs
o Manual or automatic airlock with sliding shelves
o User-friendly Control Panel Layout and microprocessor controls
o Automatic pressure controls provide positive pressure at approx. 3” of water column and shows pressure level
o Incubator located inside, top rear of chamber
o Available Installation and Training Workshop (for USA orders only)
o Two-Year Manufacturer Limited Warranty
Active Questions & AnswersAsk a Question
There are no current Discussions
Glove Boxes Service ProvidersView All (2)
Documents & Manuals
There are no Documents or Manuals available.
Features
There are no Features available.
General Specifications
There are no General Specifications available.