Features of ES NU-8600
NuTouch Electronic Control System (ECS)
Control over the functions of the CO2 incubator is provided by the NuTouch ECS. This user-friendly control system lets operators program system use, calibration procedures, alarm parameters and they can also adapt the incubator to different lab environments. The ECS has a color touchscreen to enter data and view operating control parameters and status indicators.
Precise CO2 Control
A dual wave infrared (IR) CO2 sensor measures and maintains accurate growth-chamber CO2 levels in the range of ±0.1 percent and is not affected by water vapor or other components. The single light source dual-wave design delivers stable, drift-free output that requires less frequent calibration.
Closed-Loop HEPA Filtration
The closed-loop HEPA filtration system creates an environment similar to an ISO Class 5 clean room minimizing contamination. A continuously operating air pump maintains a positive pressure growth environment as gas and air pass through the 99.99 percent efficient filters at a recirculation rate of one chamber volume change every 30 minutes.
Clean Design
The crevice-free, cove-cornered interior of the water jacket incubator discourages biological growth to help prevent contamination. It is constructed of 16-gauge polished stainless steel; a surface that is easy to keep clean and contaminant-free.
Vibration-Free Construction
The NU-8600 CO2 incubator is designed with few moving parts, minimizing potential vibration that disturbs cell lines.
Precise Temperature Control
The NU-8600 maintains accurate temperature with the large 18 gallons (68.1-liter) water jacket that surrounds the inner chamber. Heated water in this jacket circulates around the growth chamber, keeping the temperature uniform within the growth chamber ±0.2°C. Precise temperature control is aided by the R5 insulation that lines the outer chamber walls that minimize heat loss.
The door and perimeter heaters are microprocessor-controlled to adjust to the room's ambient temperature. They can also be adjusted manually from ±20 percent to reduce condensation within the growth chamber.
Faster Recovery Times
The CO2 level can recover automatically at an average rate of 5 percent in five minutes, while the temperature recovers at 0.12°C per minute. Faster recovery times ensure your cell lines remain undisturbed promoting cell growth.