BERTHOLD TECHNOLOGIES - LB 111 Micro Gamma
The LB 111 is a versatile instrument to measure local doses and doserates in one or two channels.
The LB 111 is a versatile instrument to measure local doses and dose rates in one or two channels. It can be software-programmed for manifold applications and contains all facilities for data storage and date transmission.
The instrument is operated via a foil keypad in a menu-structured dialog. Three function keys (softkeys) are located below the display and three additional function keys to the right of the display. Parameter changes are possible only via password.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byharazumiyyah9324
Elemental Analyzers Service ProvidersView All (6)
Documents & Manuals
There are no Documents or Manuals available.
Features of LB 111 Micro Gamma
- Compact measuring unit in a shielded metal housing with microprocessor card for connection of up to 2 detectors and with IP 65 tightness
- All types of gamma or neutron detectors including an internal high voltage generator and a standard pulse output are suitable for connection
- Low dose / high dose rate system
- Radioactive gas monitor
- Ratemeter or scaler timer mode
- Easy to read LCD display with background illumination
- Unidirectional RS 232 interface is available for data transfer and data communication in measuring networks; another interface is provided for printer connection
- Two electrically separated 0/4 - 20 mA analog outputs are available for connection of a recorder
- 5 freely programmable outputs for error and alarm messages, 2 programmable current outputs for analog display of the results (Option), 2 alarm thresholds and 1 integral threshold per channel, 1 fail threshold per channel (with test time interval)
- Measuring station with alarm signals (lamps, flashlight, horn) for local warning functions
- Password-protected parameter settings via softkey dialog
- Locking of essential parameters through internal DIP-switches
- Units of measurement and channel identification freely selectable
- Typ-tested and approved by the German National Bureau of Standards (PTB Braunschweig)
General Specifications
There are no General Specifications available.
Additional Specifications
Measuring modesratemeter or scaler/timer Displaytwo line 2 x 24 characters LCD display with background illumination Data storage Circular buffer (FIFO) with 120 memories (version 3.1 and higher) each for date/time, no., status, ratemeter 1, ratemeter 2, integral 1, integral 2, integral time, scaler timer 1, scaler timer 2 Temperature range-5 °C to 50 °C Relative humidity10 % to 90 % (LB 111 type-tested from 30% to 75%) Protection degreeIP 65 Dimensions240 x 195 x 202 mm³ (L x W x H) Weight 4.8 kg, metal housing