Features of Protector Pass-Through
- By-pass airflow design.
- Glacier white, dry powder epoxy-coated steel and aluminum frame.
- Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings.
- Two each 3/16" thick tempered safety glass vertical-rising sashes.
- Audible alarm that sounds when both sashes are open at the same time.
- Pre-wired 100-watt vapor-proof incandescent light.
- One pre-wired 115-volt, 20 amp GFCI electrical duplex receptacle on lower right side (one side).
- Pre-wired light and blower switches (one side).
- Removable front and side panels for access to light, electrical wiring and sash cables.
- Epoxy-coated steel 10.09" ID exhaust connection.
- 4, 5’ and 6’ widths
- Clear, 1/4" thick, 15"x 24" right-side mounted tempered safety glass side window
- Remote Blower or ducting to house exhaust
- Work Surface
- Base Cabinet or Stand
General Specifications
| Airflow (CFM) | 830 CFM |
| Depth | 33.2 in |
| Height | 59 in |
| Width | 48 in |
| Power Requirements | 115 volts, 60 Hz, Domestic |
| Lighting | 100-watt vapor proof incandescent light |
| Construction | Glacier white dry powder epoxy-coated steel exterior |
| Face Velocity (FPM) | 100 |
Additional Specifications
Product Subcategory: General Chemistry, Educational
Nominal Width: 4'
Electrical Requirements: Domestic
Blower Requirements: Remote blower required
Air Usage/Static Pressure with Sash Full Open: At 100 fpm, exhausts 830 CFM at 0.26" H2O static pressure
Air Usage/Static Pressure with Sash Open 18": At 100 fpm, exhausts 530 CFM at 0.10" H2O static pressure
Style: Benchtop
Compliance: SEFA 1-2002, NFPA 45-2000, ASTM E84-01, ASHRAE 110-95, ANSI Z9.5-1993, UL 3101-1/61010-1, CAN/CSA C22.2 No. 1010.1, UL 1805
Electrical Duplexes: 1
Other:
4' Protector Pass-Through Laboratory Hood, by-pass airflow design, 3/16" thick tempered safety glass vertical-rising independant counterbalanced sashes which have an alarm that sounds when both sashes are open at the same time, ergonomic air foils with aerodynamic Clean-Sweep openings, an optional right side viewing window is available; 10.09" ID exhaust connection, front and side access panels, glacier white dry powder epoxy-coated steel exterior.