Labconco - Protector Pass-Through

Manufactured by  Labconco
Follow this Equipment

Protector Pass-Through Laboratory Hoods offer sashes on two sides allowing operation on either side of the fume hood....

Protector Pass-Through Laboratory Hoods offer sashes on two sides allowing operation on either side of the fume hood. An audible alarm sounds to prevent simultaneous opening of both sashes. With unobstructed visibility from either side, this hood is ideal for conducting chemistry demonstrations. An optional right-side viewing window further enhances visibility. These hoods may also be installed in the wall between two rooms for sample preparation.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Updated byLabWrenchSiteAdmin

Fume Hoods Service ProvidersView All (9)

Request Support
Features of Protector Pass-Through
Features
  • By-pass airflow design.
  • Glacier white, dry powder epoxy-coated steel and aluminum frame.
  • Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings.
  • Two each 3/16" thick tempered safety glass vertical-rising sashes.
  • Audible alarm that sounds when both sashes are open at the same time.
  • Pre-wired 100-watt vapor-proof incandescent light.
  • One pre-wired 115-volt, 20 amp GFCI electrical duplex receptacle on lower right side (one side).
  • Pre-wired light and blower switches (one side).
  • Removable front and side panels for access to light, electrical wiring and sash cables.
  • Epoxy-coated steel 10.09" ID exhaust connection.
Options
  • 4, 5’ and 6’ widths
  • Clear, 1/4" thick, 15"x 24" right-side mounted tempered safety glass side window
Required Accessories
  • Remote Blower or ducting to house exhaust
  • Work Surface
  • Base Cabinet or Stand
General Specifications
Airflow (CFM) 830 CFM
Depth 33.2 in
Height59 in
Width 48 in
Power Requirements 115 volts, 60 Hz, Domestic
Lighting100-watt vapor proof incandescent light
ConstructionGlacier white dry powder epoxy-coated steel exterior
Face Velocity (FPM) 100
Additional Specifications

Product Subcategory: General Chemistry, Educational
Nominal Width: 4'
Electrical Requirements: Domestic
Blower Requirements: Remote blower required
Air Usage/Static Pressure with Sash Full Open: At 100 fpm, exhausts 830 CFM at 0.26" H2O static pressure
Air Usage/Static Pressure with Sash Open 18": At 100 fpm, exhausts 530 CFM at 0.10" H2O static pressure
Style: Benchtop
Compliance: SEFA 1-2002, NFPA 45-2000, ASTM E84-01, ASHRAE 110-95, ANSI Z9.5-1993, UL 3101-1/61010-1, CAN/CSA C22.2 No. 1010.1, UL 1805
Electrical Duplexes: 1
Other:
4' Protector Pass-Through Laboratory Hood, by-pass airflow design, 3/16" thick tempered safety glass vertical-rising independant counterbalanced sashes which have an alarm that sounds when both sashes are open at the same time, ergonomic air foils with aerodynamic Clean-Sweep openings, an optional right side viewing window is available; 10.09" ID exhaust connection, front and side access panels, glacier white dry powder epoxy-coated steel exterior.

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com