Analytik Jena - SPECORD® Plus Series
Manufactured by Analytik Jena
Routine analysis or special application in chemistry, pharmacy, medicine, food control, environment, life science and many other areas.
SPECORD® PLUS means reliability, user friendliness and flexibility for precise, very easy and versatile UV VIS analysis.
The reliability of the SPECORD® devices is significant. The 10-years long-term warranty on optical components is one concrete example for us to point that out. Operation over decades, absolutely low service rates and a constant high performance and precision of the SPECORD® are details you just have to experience yourself.
The reliability of the SPECORD® devices is significant. The 10-years long-term warranty on optical components is one concrete example for us to point that out. Operation over decades, absolutely low service rates and a constant high performance and precision of the SPECORD® are details you just have to experience yourself.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked bysang
UV/VIS Spectrophotometers Service ProvidersView All (32)
Documents & ManualsView All Documents
Features of SPECORD® Plus Series
The SPECORD® PLUS is more than ever developed for user friendly operation:
- Large, easily accessible sample compartment
- Comprehensive method collection
- Self Check System (SCS)
- Intuitive software navigation
- Automatic accessory recognition
- Multilingual software
- No warm-up phase, plug and play
Routine- or special analysis – the SPECORD® PLUS guarantees flexible operation in all areas of application. Thanks to its extensive range of accessories and the modular software concept the device provides a unique individuality.
General Specifications
There are no General Specifications available.
Series Modals
Analytik Jena - SPECORD 200 PLUS
[+] View Model SpecificationsBandwidth | Fixed 1.4 nm |
Depth | 690 mm |
Height | 260 mm |
Width | 590 mm |
Photometric Range | -3 to 3 A (up to 900 nm) |
Weight | 27 kg |
Wavelength Range | 190 to 1100 nm |
Scanning Speed | 12000 nm/min |
Light Source | Combination of Halogen and Deuterium lamp. Lamp change selectable between 300 and 450 nm. |
Optics | Double Beam |
Sample Compartment | Dimensions (W x H x D): 364 x 185 x 260 mm |
Stray Light | 198 nm (KCl Merck 1.08164.0001): 0.03% T. 220 nm (NaI): 0.03% T. 240 nm (NaI): 0.03% T. 340 nm (NaNO2): 0.02% T. |
Additional Model Specifications | Scan Application: Mode for slow scanning. Scan speed and integration time selectable. Mode: Energy, Absorption, Transmission, Reflectance Software: WinASPECT PLUS Validation: The validation software is an option with the WinASPECT PLUS software packaged. In compliance with Ph. Eur., USP, ASTM, TGA (Australia). All manufacturing performance tests and other specification tests are provided. Technical Standards: Tested and designed to be compliant with the legal requirements for laboratory instrumentation and developed and produced in compliance with ISO 9001. SPECORD PLUS series instruments are certified to comply with the requirements of the EMC standards and bear the CE mark. Photometric Display: -8 to 8 A UV-Resolution (toluene,hexane): 1.6 Wavelength Accuracy (Deuterium line at 656 nm): ±0.1 nm Wavelength Reproducibility (with Holmium oxide filter*): ±0.02 Photometric Accuracy: VIS at 546 nm with Neutral glass filter Hellma F4** ±0.003. UV with Potassium dichromate according Ph. Eur. ± 0.01 A Baseline Stability at 500 nm: 0.0001 (RMS) Longterm Stability at 500 nm: ±0.0005 *With slit width 1 nm, 20 degree, ** Summary of the tolerances from the filters and spectrometers. |
Analytik Jena - SPECORD 210 PLUS
[+] View Model SpecificationsBandwidth | Variable 0.1/ 1/ 2/ 4 nm |
Depth | 690 mm |
Height | 260 mm |
Width | 590 mm |
Weight | 27 kg |
Wavelength Range | 190 to 1100 nm |
Scanning Speed | 12000 nm/min |
Light Source | Combination of Halogen and Deuterium lamp. Lamp change selectable between 300 and 450 nm. |
Optics | Double Beam |
Sample Compartment | Dimesions (W x H x D): 364 x 185 x 260 mm |
Stray Light | 198 nm (KCl Merck 1.08164.0001): 0.03% T. 220 nm (NaI): 0.03% T. 240 nm (NaI): 0.03% T. 340 nm (NaNO2): 0.01% T. |
Additional Model Specifications | Scan Application: Mode for slow scanning. Scan speed and integration time selectable. Mode: Energy, Absorption, Transmission, Reflectance Software: WinASPECT PLUS Validation: The validation software is an option with the WinASPECT PLUS software packaged. In compliance with Ph. Eur., USP, ASTM, TGA (Australia). All manufacturing performance tests and other specification tests are provided. Technical Standards: Tested and designed to be compliant with the legal requirements for laboratory instrumentation and developed and produced in compliance with ISO 9001. SPECORD PLUS series instruments are certified to comply with the requirements of the EMC standards and bear the CE mark. Photometric Display: -8 to 8 A Photometric Range: -3 to 3 A (up to 900 nm) UV-Resolution (toluene,hexane): 2.3* Wavelength Accuracy (Deuterium line at 656 nm): ±0.1 nm Wavelength Reproducibility (with Holmium oxide filter*): ±0.02 Photometric Accuracy: VIS at 546 nm with Neutral glass filter Hellma F4** ±0.003. UV with Potassium dichromate according Ph. Eur. ± 0.01 A Baseline Stability at 500 nm: 0.0001 (RMS) Longterm Stability at 500 nm: ±0.0005 *With slit width 1 nm, 20 degree, ** Summary of the tolerances from the filters and spectrometers. |
Analytik Jena - SPECORD 250 PLUS
[+] View Model SpecificationsBandwidth | Variable 0.1/ 1/ 2/ 4 nm |
Depth | 690 mm |
Height | 260 mm |
Width | 590 mm |
Photometric Range | -4 to 4 A (up to 900 nm) |
Weight | 27 kg |
Wavelength Range | 190 to 1100 nm |
Scanning Speed | 12000 nm/min |
Light Source | Combination of Halogen and Deuterium lamp. Lamp change selectable between 300 and 450 nm. |
Optics | Double Beam |
Sample Compartment | Dimensions (W x H x D): 364 x 185 x 260 mm |
Stray Light | 198 nm (KCl Merck 1.08164.0001): 0.03% T. 220 nm (NaI): 0.005% T. 240 nm (NaI): 0.005% T. 340 nm (NaNO2): 0.005% T. |
Additional Model Specifications | Scan Application: Mode for slow scanning. Scan speed and integration time selectable. Mode: Energy, Absorption, Transmission, Reflectance Software: WinASPECT PLUS Validation: The validation software is an option with the WinASPECT PLUS software packaged. In compliance with Ph. Eur., USP, ASTM, TGA (Australia). All manufacturing performance tests and other specification tests are provided. Technical Standards: Tested and designed to be compliant with the legal requirements for laboratory instrumentation and developed and produced in compliance with ISO 9001. SPECORD PLUS series instruments are certified to comply with the requirements of the EMC standards and bear the CE mark. Photometric Display: -8 to 8 A UV-Resolution (toluene,hexane): 2.3* Wavelength Accuracy (Deuterium line at 656 nm): ±0.1 nm Wavelength Reproducibility (with Holmium oxide filter*): ±0.02 Photometric Accuracy: VIS at 546 nm with Neutral glass filter Hellma F4** ±0.003. UV with Potassium dichromate according Ph. Eur. ± 0.01 A Baseline Stability at 500 nm: 0.0001 (RMS) Longterm Stability at 500 nm: ±0.0005 *With slit width 1 nm, 20 degree, ** Summary of the tolerances from the filters and spectrometers. |