OI Analytical - S-PRO 3200 GC System for Sulfur Analysis
Manufactured by OI Analytical
The S-PRO 3200 is a custom-configured gas chromatograph for selective, high-sensitivity measurement of sulfur compounds...
The S-PRO 3200 is a custom-configured gas chromatograph for selective, high-sensitivity measurement of sulfur compounds in gas-phase samples and Liquified Petroleum Gas (LPG) streams (such as propylene and ethylene).
The key technology within the S-PRO is the 5383 PFPD, which has a linear equimolar response to sulfur allowing selective measurement of individual sulfur species from low ppb to ppm levels, and total sulfur as the sum of individual peaks.
We have integrated a number of special design features into the System’s GC platform, the Agilent 7890 GC System, to provide unique analytical and performance capabilities.
The key technology within the S-PRO is the 5383 PFPD, which has a linear equimolar response to sulfur allowing selective measurement of individual sulfur species from low ppb to ppm levels, and total sulfur as the sum of individual peaks.
We have integrated a number of special design features into the System’s GC platform, the Agilent 7890 GC System, to provide unique analytical and performance capabilities.
Active Questions & AnswersAsk a Question
There are no current Discussions
GC Detectors Service ProvidersView All (1)
Documents & ManualsView All Documents
Features of S-PRO 3200 GC System for Sulfur Analysis
- Provides automated sample injection, calibration, and QA/QC * Integrated permeation oven provides single or multiple calibration or QC standards * Automated injection of calibration or check samples provided by the built-in valving and permeation system eliminates using unstable, expensive sulfur gas standards * OI Volatiles Interface, optimized for valve injection, provides low dead volume split or splitless injection for a wide dynamic range * Sulfinert™-treated sample pathway minimizes absorptive surfaces for optimal performance, particularly for low sulfur concentrations * Proven PFPD detector provides stability, sensitivity, selectivity, equimolar sulfur response, calibrations in linear or quadratic modes, and multi-element detection capability * Single-digit ppb sensitivity for sulfur analysis * Full EPC control of all injector, permeation oven, and detector gases * Using additional or alternative detectors (PID, ELCD, XSD, or tandem configurations) allows the analysis of other compounds of interest
General Specifications
There are no General Specifications available.