AirClean® Systems - TeachAide Classroom Demonstration Workstation
Student and teacher protection with 360° classroom engagement
Teachaide™ Demonstration Fume Hoods have been independently tested to the educational science laboratory curriculum. Each demonstration workstation is factory tested and shipped fully assembled with filters installed.
AirClean® Systems TeachAide™ ductless classroom demonstration workstation is shipped fully assembled.
AirClean® Systems TeachAide™ Ductless Classroom Demonstration Fume Hoods are safe, economical, and provide an excellent hands-on teaching tool for science teachers.
AirClean® Systems recognizes that science experiments are a necessary part of the curriculum and demonstrations play a vital role in the learning experience. Preparation, demonstration, and clean-up are peak exposure times. The TeachAide™ ductless classroom demonstration workstation is the final piece of the puzzle for hands-on science experiments in today's science classroom.
Filtration is at the heart of a ductless fume hood and AirClean® Systems utilizes a revolutionary bonded carbon filter that provides both effective containment of toxic vapors, gases and fumes while minimizing potential exposure to hazardous carbon dust. Suspended in a predictable matrix, carbon pellets are evenly distributed throughout the filter. This allows for maximum capture, thus yielding a higher load capacity for AirClean® Systems filters compared to traditional pelletized carbon filter.
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & Manuals
There are no Documents or Manuals available.
Features of TeachAide Classroom Demonstration Workstation
Standard Features
AirSafe™ automatic safety controller * Integral base with deep spill lip * Clear polycarbonate shell for 360° visibility * No ductwork required * No installation required - plugs directly into a standard 110V or 220V electrical outlet * Extremely quiet operation < 49dBA * Gas phase bonded carbon filtration * Lab event timer * HEPA filtration for capture of particulate to 0.3 microns in size
Safety Features * Brushless, sparkless blower is post-filter * Deep base effectively contains accidental spills * Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas * Filter safety lockout to ensure correct filter replacement * Flame-retardant pre-filter * Low airflow alarm warns the user both visually and audibly * Real time monitoring of installed filtration bed * Shipped fully assembled * Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1
General Specifications
There are no General Specifications available.