Thermo Scientific - LTQ Velos Dual-Pressure Ion Trap

Manufactured by  Thermo Scientific
Follow this Equipment

World's fastest and most sensitive ion trap mass spectrometer

The Thermo Scientific LTQ Velos is the latest evolution in the award winning LTQ family of linear ion trap mass spectrometers. Building on a tradition of innovation, the LTQ Velos™ provides the analyst with significantly enhanced performance for complex sample analyses.   
  
The innovative dual-pressure ion trap and S-Lens ion optics combine to deliver increased ion transmission along with better trapping and fragmentation efficiency. The result is the fastest and most sensitive ion trap for all applications.  
  
Continuing a commitment to providing researchers with the latest in high-performance mass spectrometers, the LTQ Velos is fully upgradeable with electron transfer dissociation (ETD) and Orbitrap™ technology to extend its capabilities even further.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Features of LTQ Velos Dual-Pressure Ion Trap

The LTQ Velos is the latest evolution in the award winning LTQ family of linear ion trap mass spectrometers. It offers significant improvements in data acquisition rate, sensitivity, and mass resolution.  

Key Features  

  • S-Lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate  
  • More efficient dual-pressure ion trap simultaneously increases scan speed and mass resolution  
  • Predictive Automatic Gain Control reduces cycle times, yielding improved data acquisition rates  
  • Improved sensitivity and mass resolution increase confidence in identification of low-level analytes  
  • Increased performance enables simultaneous identification, structural elucidation, and quantification of complex samples  
  • Upgradeable to the ultra-high resolution and outstanding mass accuracy of Orbitrap* technology
General Specifications
Depth 146.3 cm
Height141.4 cm
Mass Range200 to 4000 m/z
Width 87 cm
Weight620 kg
Mass Spectrometer TypeIon-Trap Mass Analyzer
Additional Specifications

Software Features  
Data System  
Thermo Scientific Xcalibur processing and instrument control software  
Microsoft® Office XP software package  
Microsoft Windows® XP operating system  
High-performance PC with Intel® microprocessor  
High-resolution LCD color monitor  
  
Scan Functions  
Full-scan feature provides full-scan mass spectra for sensitive analyses and produces spectra for rapid screening of unknown compounds.  
Selected ion monitoring (SIM) monitors selected ions for target compound analysis.  
Full-scan MS/MS produces full-scan product ion spectra selected reaction monitoring (SRM) for a traditional LC-MS/MS quantitative analytical experiment.  
MSn for multi-stage MS experiments to probe the structure of ions.  
ZoomScan™, a high-resolution, full-range scan to resolve isotopic envelopes which is often used for charge state determination of peptides and ionization state determination of organometallics.  
Ultra ZoomScan for ultimate resolution.  
TurboScan™, an ultra-fast scan to improve signal-to-noise and sampling rate.  
  
Exclusive Technologies  
Unique, patented Automatic Gain Control (AGC) ensures that the ion trap is always filled with the optimum number of ions for any scan type.  
Dynamic Exclusion™ allows acquisition of MS/MS and MSn spectra from lower intensity ion species.  
WideBand Activation™ generates more structurally informative spectras.  
Normalized Collision Energy™ provide reproducible data from instrument to instrument.  
  
System Specifications  
MS/MS Sensitivity  
Electrospray Ionization (ESI) –2 µL of a 50 fg/µL solution of reserpine (100 femtograms total) injected at a flow of 500 µL/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the  
largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 – 615.  
  
Atmospheric Pressure Chemical Ionization (APCI) – 2 µL of a 50 fg/µL solution of reserpine (100 femtograms total) injected at a flow of 500 µL/min will produce a minimum signal-to noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, 397 and 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 – 615.  
  
Installation Requirements  
Power  
One 230 Vac ±10.0%, 15 Amps, 50/60 Hz, single phase, with earth ground dedicated to the instrument.  
120 or 230 Vac single phase, with earth ground for the data system.  
  
Gas  
One high-purity (99% pure, flow rate 15 L/min) nitrogen gas supply for the API source.  
One ultra-high-purity helium gas supply (99.998% pure) with less than 1 ppm each of water, oxygen, and total hydrocarbons for the mass analyzer.  
  
Environment
  
System averages 2300 W (8000 BTU/h) output when considering air conditioning needs.  
Operating environment must be 15-27 °C (59-80 °F) and relative humidity must be 40-80% with no condensation.  
Optimum operating temperature is 18-21 °C (65-70 °F).  
  
Dimensions/Weight  
MS: 56 cm · 79 cm · 59 cm (h · w · d)  
MS: ~120 kg  
Roughing pumps: 38.6 kg  
  
Performance Specifications  
Mass Range  
m/z 15 – 200  
m/z 50 – 2000  
m/z 200 – 4000  
  
Resolution  
0.05 FWHM (full width half maximum) with Ultra ZoomScan  
  
Scan Power  
MSn, for n = 1 through 10  
  
Analog Inputs  
One (1) analog Input (0-1 V)  
One (1) analog Input (0-10 V)