Shimadzu - GCMS-QP2010S
Mass Spectrometer Systems
It upholds the Shimadzu GCMS tradition of delivering innovative products designed specifically for customers' needs.
Active Questions & AnswersAsk a Question
GC-Single Quad/MSD Service ProvidersView All (1)
Documents & ManualsView All Documents
Features of GCMS-QP2010S
- Direct Inlet - The DI-2010 Direct Inlet option allows users to input samples directly into the ion source at temperatures up to 500°C without disconnecting the chromatograph. It delivers the fastest sample identification available.
- Additional Detectors - The GCMS-QP2010S Series has the ability to add additional detectors (FID, TCD, ECD, FPD, FTD).
- Libraries - Classical spectrum permits rapid identification of unknowns using several commercial libraries (e.g., NIST, Wiley, Pesticides, Polymer Additives, etc.), making the GCMS-QP2010S ideal for a variety of high-throughput applications.
- Accessories - Choose from a number of accessories, including the AOC-20i/s, and PY-2020 Pyrolyzer, for sampling flexibility or to create an application-specific system.
General Specifications
| Mass Spectrometer Type | Quadrupole Mass Analyzer |
Additional Specifications
[u]Performance[/u]
Mass range: m/z 1.5 to 900
Mass resolution: R> 2M
Sensitivty (EI)*:
Scan, 1 pg octafluoronaphthalene
m/z 272 S/N > 30 (RMS)
SIM, 100 fg octafluoronaphthalene
m/z 272 S/N > 30 (RMS)
Max. Scan Rate: 10,000 u/sec (Single Scan), allows measurement with 0.1 sec san interval for 0.1u step from m/z 60 to 660 (600u)
Min. Scan Interval: 20 ms (allows max. 50 scans/sec)
[u]Instrument[/u]
[i]GC[/i]
Model: Shimadzu GC-2010
Injector Port Temp: Up to 450 °C
AFC Pressure Range: 0 to 970kPa
Column Oven Temp: Up to 450 °C
High power oven with fast heat-up rate compatible with fast GC/MS (230VAC)
[i]MS[/i]
--- GCMS Interface ---
Type: Direct Connection with capillary column
Temperature: Up to 350 °C
--- Ion Source ---
Mode: EI
Ion Source Temperature: 100 to 260 °C
Filament: Dual (Automatic Switching)
Electron Energy: 10 to 200 eV
Emission Current: 10 to 250 µA
Front Access Structure for easy maintenance.
--- Mass Analyzer and Detector ---
Mass Analyzer: Metal quadrupole mass filter with pre-rod
Mass Stability: +/- 0.1u /48 hrs (constant temp.)
Detector: Electron multiplier with the patented over-drive lens system for noise reduction
Dynamic Range: 8 x 106 (Electronic)
--- Vacuum System ---
Main Pump: Turbomolecular pump (65 L/sec for He)
Fore-pump: 30L/min (60Hz) Rotary Pump
Column Flow: Up to 2 mL/sec
[i]DI (Option)[/i]
Temp. Setting: Room Temp. to 500 °C
Usable without removing the GC column.
[u]Power Requirements[/u]
Frequency: 50/60 Hz
[i]GC:[/i] 1800VA (115VAC) / *2600VA(230VAC)
*High power oven
[i]MS:[/i] 1000VA (100 - 230VAC)
[u]Environment[/u]
Temperature: Constant temperature between 18 to 28 °C
Humidity: 40 to 70 % (No Condensation)
[u]Weight[/u]
[i]GC and MS:[/i] 68 kg
[i]Rotary pump:[/i] 10 kg