Brookhaven Instruments - BI-200SM

Manufactured by  Brookhaven Instruments
Follow this Equipment

Research Goniometer and Laser Light Scattering System - The Brookhaven Approach to Light Scattering

Light Scattering occurs when polarizable particles in a sample are bathed in the oscillating electric field of a beam of light. The varying field induces oscillating dipoles in the particles and these radiate light in all directions. This important and universal phenomena is the basis for explaining why the sky is blue, why fog and emulsions are opaque and other observations. It has been utilized in many areas of science to determine particle size, molecular weight, shape, diffusion coefficients etc. Brookhaven Instruments' scientists have extensive experience in the development of instruments and methods for light scattering and this experience has been incorporated into the BI-200SM to make it the finest instrument available for research applications of light scattering.

With a Brookhaven Instruments BI-200SM system this rich field of exploration is open to you for studies of both Static Light Scattering (SLS) and Dynamic Light Scattering (DLS).

The Bl-200SM Research Goniometer System provides access to all of these studies with an automatic, modular and versatile system. It is a precision instrument designed for exacting scattering measurements. Based on a special turntable with precision ball bearings and stepping motor, the Bl-200SM's modern design and quality construction guarantee precise measurements due to the wobble-free movement of the detector. It is field proven in hundreds of laboratories. It is ideal for macro-molecular studies and submicron particle sizing.

NEW! By taking advantage of the multiple inputs available on the TurboCorr correlator a new capability of the 200SM system is created. By adding an optical signal splitter to the beam of scattered light and a second detector it is possible to eliminate the effects of very high speed interference from the detector(s). This Cross Correlation System provides remarkably clean information as seen in the article we have presented.

The BI-200SM's modularity simplifies system expansion. Featuring a standard optical rail, the BI-200SM can be used with neutral density filters, a polarizer, an analyzer, and a reference detector. Special sample requirements can often be met by changing the cell holder design or size.
Active Questions & AnswersAsk a Question

There are no current Discussions

Particle Size Analyzers Service ProvidersView All (2)

Request Support
Features of BI-200SM

Features Include:

  • Stepping motor controlled, multiangle measurements
  • Particle size and size distributions
  • Mw, Rg, A2 for dilute polymer solutions
  • Cross-correlation detector option
  • Avalanche photodiode detector option
  • CONTIN, Zimm, Guinier, Fractal, and more

Special Features Include:

Both DLS and SLS modes:

Correlation & Intensity Measurements Large angular Range: 8° to 155° with 25mm cells: 15° to 155° with 12mm cells.

Fine Adjustment Control:

Read angle to 0.01° directly on large, fine-control adjustment knob.

Open Design/Standard Optical Rails:

Facilitates user customizations for special purposes.

Temperature Control:

Heating and cooling via any standard external circulator Separate temperature and filtration plumbing.

Special Design Glass Vats:

Specially polished and flat entrance window ensures minimum flare.

Alignment Cell:

Fine-screw vertical adjustment makes finding the center of rotation easier.

Multiple Laser Line Filters:

Filter wheel with 632.8 (HeNe), 514.5/488.0 nm (Ar+), one open position for weak scatterers, and 2 blank (shutter) positions. Also available with 532 nm bandpass filter

Enhanced Viewing Optics:

Coated, precision achromats coupled with behind-the-slit viewing and high-quality eyepiece make alignment easier.

Additional Alignment Aperture:

Alignment of laser much simpler and faster.

Variety of Cell Holders:

High precision cell holders standard, low-priced round cells available: 27.5 mm dilution vials fit cell holder sleeve. Special small-volume cell available.

General Specifications

There are no General Specifications available.

Additional Specifications

Beam Focus and Steering: Includes mounts, adjustments, and apertures.

Turntable: 200 mm O.D. turntable, worm gear and ball bearings; manual or automatic selection of angles in 0.01° steps; precision machined base with mounting holes; positioning table with micrometer adjustments. (Power supply and controller for stepping motor is optional)

Specimen Cell Assembly: Including thermal enclosure, centering adjustments, separate plumbing for temperature control and index matching liquids, round cell holders, square cell holder and alignment cell.

Index Matching Vat:
With optically flat and specially polished entrance window; precision machined and annealed to minimize stray light.

Periscopic Beam Stop: Located inside vat to prevent flare from exit window; provided with coupling for use with optional, zero-angle reference detector.

Main Detector Optics:


  1. Entrance aperture of 3 mm.
  2. Coated, adjustable achromat for focusing scattered light onto 200 micron slit. Slit position adjustable.
  3. Reflex mirror and high quality eyepiece for viewing scattering region through slit.
  4. Filter turret with 632.8, 514.5, 488.0 nm, 2 closed positions, and 1 open position. other filters available.
  5. Secondary pinhole turret: 100, 200 and 400 micron pinholes for DLS measurements; 1, 2 and 3 mm pinholes for SLS measurements.


A policy of continual improvement may lead to specification changes.

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com