VistaLab Technologies - Ovation - Adjustable Volume
Manufactured by VistaLab Technologies
Ergonomically-correct adjustable volume pipettes.
Adjustable volume models allow five of the laboratory’s most frequently-used volumes to be set-up and stored for routine use and later recall. Other volume settings can be selected at precise increments throughout the pipette’s range. A low-force, form-fitting plunger manually controls aspiration and dispensing speeds with minimal effort. This is especially important for samples containing cells with fragile membranes that can be easily disrupted, or fluids that tend to bubble. A Starter Pack that includes 3 pipettes, a pipette stand and tips is available at a special price.
Active Questions & AnswersAsk a Question
There are no current Discussions
Pipettes Service ProvidersView All (10)
Documents & ManualsView All Documents
Features of Ovation - Adjustable Volume
Easy tip acquisition & discard With the Ovation pipette, an audible "click" indicates that the tip is securely sealed onto the pipette and ready for use. And Ovation requires far less force to discard tips than traditional pipettes – just the gentle push of a button.
Minimal exertion with every sample A very low-force, form-fitting plunger allows the user to manually control the speed of aspirating and dispensing with minimal effort.
Easy access to pre-set volume settings Five frequently-used aspirating and
dispensing volumes can be quickly selected for use at just the touch of a button.
In-lab calibration made simple Adjustments are easy when compensation is
needed for environmental conditions or different liquid types – without tools! Returning to factory settings (or any setting) is made instantly at the touch of a button.
General Specifications
There are no General Specifications available.
Series Modals
VistaLab Technologies - 0.2-2 µL
[+] View Model Specifications| Maximum Dispensing Volume | 2 μL |
| Channel(s) | 1 |
| Dispensing Volume Range** | 0.2-2 µL |
| Increment | 0.002 μL |
| Pipette Accuracy | ±1.5% at 2 µL, ±2.7% at 1 ?L, ±9% at 0.2 ?L |
| Pipette Precision | 0.9% at 2 µL, 1.8% at 1 ?L, 7.6% at 0.2 ?L |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Variable |
| Additional Model Specifications | Colour: Red |
VistaLab Technologies - 1-10 µL
[+] View Model Specifications| Maximum Dispensing Volume | 10 μL |
| Channel(s) | 1 |
| Dispensing Volume Range | 1 to 10 μL |
| Dispensing Volume Range** | 1-10 µL |
| Increment | 0.01 μL |
| Pipette Accuracy | ±1% at 10 µL, ±1.5% at 5 ?L, ±2.5% at 1 ?L |
| Pipette Precision | 0.4% at 10 µL, 0.6% at 5 ?L, 1.2% at 1 ?L |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Variable |
| Additional Model Specifications | Colour: Orange |
VistaLab Technologies - 10-100 µL
[+] View Model Specifications| Maximum Dispensing Volume | 100 μL |
| Channel(s) | 1 |
| Dispensing Volume Range | 10 to 100 μL |
| Dispensing Volume Range** | 10-100 µL |
| Increment | 0.1 μL |
| Pipette Accuracy | ±0.8% at 100 µL, ±0.8% at 50 ?L, ±3.5% at 10 ?L |
| Pipette Precision | 0.15% at 100 µL, 0.24% at 50 ?L, 1% at 10 ?L |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Variable |
| Additional Model Specifications | Colour: Green |
VistaLab Technologies - 100-1000 µL
[+] View Model Specifications| Maximum Dispensing Volume | 1000 μL |
| Channel(s) | 1 |
| Dispensing Volume Range | 100 to 1000 μL |
| Dispensing Volume Range** | 100-1000 µL |
| Increment | 1 μL |
| Pipette Accuracy | ±0.8% at 1000 µL, ±0.8% at 500 ?L, ±3% at 100 ?L |
| Pipette Precision | 0.15% at 1000 µL, 0.2% at 500 ?L, 0.6% at 100 µL |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Variable |
| Additional Model Specifications | Colour: Purple |
VistaLab Technologies - 2-20 µL
[+] View Model Specifications| Maximum Dispensing Volume | 20 μL |
| Channel(s) | 1 |
| Dispensing Volume Range | 2 to 20 μL |
| Dispensing Volume Range** | 2-20 µL |
| Increment | 0.02 μL |
| Pipette Accuracy | ±1% at 20 µL, ±1.5% at 10 ?L, ±7% at 2 ?L |
| Pipette Precision | 0.3% at 20 µL, 0.5% at 10 ?L, 2% at 2 ?L |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Variable |
| Additional Model Specifications | Colour: Yellow |
VistaLab Technologies - 20-200 µL
[+] View Model Specifications| Maximum Dispensing Volume | 200 μL |
| Channel(s) | 1 |
| Dispensing Volume Range | 20 to 200 μL |
| Dispensing Volume Range** | 20 - 200 µL |
| Increment | 0.2 μL |
| Pipette Accuracy | ±0.8% at 200 µL, ±0.8% at 100 ?L, ±2.5% at ?L |
| Pipette Precision | 0.15% at 200 µL, 0.25% at 100 ?L, 1% at 20 ?L |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Variable |
| Additional Model Specifications | Colour: Blue |