Qsonica - Sonicator 4000
The world's most advanced ultrasonic processor.
The Sonicator tracks frequency changes in the convertor / tip assembly caused by load and temperature changes and maintains electrical efficiency at all times. This results in more efficient operation and consistent, reproducible results. Self diagnostics and help screens make operation simple and trouble-free.
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & ManualsView All Documents
Features of Sonicator 4000
Fully Digital Design Digital signal processing enables precise control of amplitude and output power. The result is consistent and reproducible sample processing.
Amplitude Control Output amplitude is controlled from 1-100% giving a greater degree of resolution and the ability to pinpoint the amplitude needed to effectively process your sample.
Expandable Operating System Software updates and new features can be downloaded to the Sonicator through the USB port located on the back of the unit. Programs can be e-mailed to the end user and uploaded in minutes. This feature ensures the Sonicator 4000 will always be at the forefront ultrasonic processing.
Touch Screen Control A large, color LCD touch screen clearly displays all operating parameters and options.
Self Diagnostics In the event that a problem is detected, the sonicator will prompt the user that an error has occurred. Help screens offer step by step instructions to help solve the problem.
Programmability Parameters including processing times, pulse on/off and amplitude can be saved to memory and run by the touch of a button.
Amplitude Control Output amplitude is controlled from 0-100% giving a greater degree of resolution and the ability to pinpoint the amplitude needed to effectively process your sample.
Pulse Mode Adjustable pulse On and Off times can be programmed from 1 second to 24 hours.
Run Multiple Programs in Sequence Multiple programs can be run in sequence. For example, the unit can be programmed to sonicate at 50% amplitude for 5 minutes, shut off for 2 minutes and re-start at 25% amplitude for 10 minutes. Up to 6 programs can be run in succession.
Total Energy Output Display Energy delivered to the probe is displayed in both Watts and Joules.
Auto Tuning The Sonicator digitally tracks frequency changes in the convertor / tip assembly caused by load and temperature changes and maintains electrical efficiency at all times. Manual tuning (common on older systems) is not necessary.
Overload Protection The unit is equipped with fault detection circuitry to shut down sonication in the event that an error is detected.
Temperature Monitoring An optional temperature probe is available for those customers who wish to monitor the temperature of their sample. If the temperature limit is reached, sonication shuts down to prevent overheating of the sample.
RoHS Compliant The new Sonicator is built lead free.
Part # S-4000 includes the following components:
- Generator
- Converter
- Converter Cable
- 1/2" replaceable tip horn
- Power Cable
- Wrench Set
- Owner's Manual
General Specifications
Depth | 20 in |
Height | 5.5 in |
Timer | 1 second to 72 hours |
Width | 11 in |
Additional Specifications
Maximum Power Output: 600 Watts
Operating Frequency: 20 kHz
Input: 100 - 240V, 50 - 60Hz
Programmability: 10 memories plus sequencing
Adjustable Pulse On/Off: 1 second to 24 hours