Burkard Scientific - FIA2000 Multi-channel Flow Injection Analyser

Manufactured by  Burkard Scientific
Follow this Equipment

The FIA2000 is a multi-channel fast automatic analysis system using flow injection. Full range of quick-change...

The FIA2000 is a multi-channel fast automatic analysis system using flow injection. Full range of quick-change chemistry manifolds for nutrients, food, water, quality control and other applications.

FIA 2000 is an advanced multi-use high precision flow injection analyser for the discriminating chemist. Based on colorimetric or UV detection, it has been designed for economy and ease of use essential to the modern laboratory.

There are many established uses for flow injection. Popular applications include

  1. Waters
  2. Soil samples
  3. Landfill samples
  4. Fertilisers
  5. Food and drinks
  6. Chemicals/Pharmaceuticals
  7. Method development
  8. Quality control

FIA 2000 will analyse nutrients, ions and metals. Burkard methods combine the latest improvements in performance with low reagent consumption. FIA 2000 offers a wide analytical choice using the additional techniques of ion selective electrodes, chemiluminescence or fluorescence. Because of this it is suitable for the user with small sample quantities but it is equally at home with routine analysis. Internationally certified methods are used where applicable. Please ask for our Applications List or Data Sheet.

The Instrument

FIA2000 comprises 3 separate units

  1. Basic Analytical Module
  2. Automatic Sample Presentation
  3. Data Capture

You can purchase just what you need. Your analysis can start immediately with the analytical module. You can add a sample changer or the low-cost manual injection timer. You can expand further with full data capture and control. The innovative Windows™ based MicroStream introduces a new dimension in advanced laboratory programming.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Features of FIA2000 Multi-channel Flow Injection Analyser
  • Fast sample analysis times
  • Up to 6 channels
  • Up to 4 simultaneous heated methods
  • Easy interchange of chemistry manifolds
  • Vertical mounted chemistry modules for smaller analyser footprint
  • Integral detector (colorimeter only)
  • Wide choice of detectors for maximum performance
  • Windows™ data processing and control

Performance

With analysis speeds up to 120 samples per hour and detection limits down to ppb levels flow injection analysis performs well compared with other techniques. Special design features of the FIA 2000 produce fast high quality analysis.

Sampling options

FIA 2000 offers you fully automatic sampling with a choice of carousel or XYZ sample changer. Automatic dilution of over-range samples is available as an option on the XYZ. However to alleviate the need for dilution the MicroStream data-processor has an extended concentration range enabling the results to be printed out at up to 10 times the normal calibration standard. When the instrument is not used with a sample changer a low-cost manual injection timer is available to ensure precise loop filling. In addition, each valve has a manual injection button as standard to assist you with setting up of the individual chemistries.

The manifold system

Standard components are used to construct the plug-in chemistry manifolds. Ready assembled units are available for the most commonly used methods. Where possible a single manifold can mount two related chemistries. Pump tube and valve connections are conveniently positioned and colour coded for identification. It takes only minutes to make a change of method.

Detectors

The in-built standard high sensitivity colorimetric and UV detectors use filter technology and flow through cells with a range of path lengths from 3-50mm. Free standing alternative detectors for Chemiluminescence, Fluorescence, and Ion Selective Electrode, interface with the chemistry manifold using the appropriate couplings. A range of flow cells are available for ISE measurements. The electrode should be specified when ordering.

Data capture and processing

FIA 2000 comes with MicroStream, a powerful multi-tasking system based on Windows™ software. MicroStream will speed up your calculating and reporting. Starting with a low-cost package for single-channel use, this system can be expanded to run up to four independent multi-channel analysers. Quality control software checks the accuracy of analysis and all results can be downloaded to other software packages and LIMS. MicroStream is compatible with Windows™ based networks.

Total Automation

All Burkard analysers can be fitted with the computer controlled automatic start-up and shut-down. A motorised wash/reagent changeover system ensures that all reagent lines are automatically connected to a water-wash on completion of analysis. The computer returns the valve to reagents for restart. Other computer control options are possible, e.g. reagent level sensing, special functions and interfacing to other instruments.

Standard chemistry methods

Data sheets are available and supplied with every method. Full information on the make-up of standards, preparation of individual chemicals and wash materials, sampler settings, optical filters and manifold connections is included. Method development is available for specific applications.

Servicing

The design of SERIES 2000 analysers mean that your servicing routine is minimal. Only the regular change of pump tubes by the user is required for routine operation. Annual and bi-annual service contracts will keep your instrument professionally maintained.

General Specifications

There are no General Specifications available.

Additional Specifications

Flow Injection Module
Injection Valve: Automatic single or multi-valve system (4 valves standard)
Sample volume: Variable loop (minimum volume 10ml)
Pump capacity: Up to 25 channels
Pump delivery: 0.12 - 12 ml/min
Pump tubing: PVC, Viton, Tygon, Silicon
Chemistry tray: Accommodates plug in manifolds with reaction coils, dialysers, ‘T’ connectors and components
Mixing coil: PTFE: 0.6mm I.D., coil lengths: 15, 20, 30, 50 & 80cm
Heating bath: Temperature variable 30° C-160° C with proportional control and display
Dimensions: 610mm x 43mm x 20mm
Supply voltages: 110/240V, 50/60Hz (to be specified)

Detector: Colorimeter
Light sources: Halogen or deuterium (UV)
Flow cells: 12mm sq. quartz window (flow through), Burkard non-debubbling flow cells 3, 5, 15 and 50mm path length
Output: Analogue 0-13V with variable gain and damping
Supply voltages: 110/240V, 50/60Hz (to be specified)
Dimensions: 410mm x 180mm x 160mm
Optional detectors: ISE, Chemiluminescence, Fluorescence

Sample Changer: Carousel or XYZ
Capacity: Carousel: 8-160 place (sample cups 2ml - 35ml volume), XYZ: 300 place
Sample time: 1-999 secs
Wash time: 1-999 secs
Sample setting: Keyboard entry
Dimensions: Carousel: 330 x 330 x 200 mm, XYZ: 560 x 480 x 340mm
Supply voltage: 110/240V, 50/60Hz (to be specified)

Flat Bed Recorder
Input sensitivity: 0-1, 2, 5, 10, 20 ,50, 100, 200, 500mV, 1, 2, 5, 10, 20 ,50V. Full scale deflection 250mm
Chart speeds: 1, 2, 3, 6, 10, 15, 30, 60cm/min & hr
Dimensions: 376 x 425 x 105mm
Supply voltages: 240V, 50/60Hz

Data Analyzer: MicroStream for Windows™
Computer: Microsoft Windows™ based PC. (Please call for latest spec.)
Processor: Second analogue processor board (ISA) for peak analysis.
Channels: Up to 16 independent channels. Channels distributed in any combination over systems
Speed: Measures narrow (2-10 seconds) and wide (several minutes) peaks at up to 300 peaks per hour per channel
Resolution: Separate 16 bit ADC on each channel gives 0.025% resolution over normal range with x5 extension for over-range samples
Sampler control: Included as standard, also random access control
System control: Options for automatic start-up and close-down
Results output: Configurable print-out modes and export to spreadsheet or database management software
LIMS interface: Configurable bi-directional link to LIMS for worksheet acquisition and down-loading of results
Internal correction: Full baseline and sensitivity drift correction plus carry-over compensation
Supply voltages: 110/240V, 50/60Hz

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com