Features of COM-300A
    COMPACT!
  • All components are integrated in a small footprint of 31 cm (W) x 27 cm (D).
  • Saves valuable bench space. FLEXIBLE!
  • Performs acid/base, redox, precipitation and complexometric titrations.
  • Combining optional KF kit, performs Karl Fischer moisture determination.
  • A wide selection of electrodes POWERFUL!
  • 30 user defined methods plus 3 KF methods can be stored in memory and easily recalled according to samples.
  • Up to 50 results with titration curve can be stored with statistics calculation. SATISFACTION!
  • Equipped with two RS-232C ports for balance and computer connection.
  • Standard package includes AQUANet data download software, instruction movie, application guidebook and more.
General Specifications
Depth 270 mm
mV Range-2000 to 2000
Height310 mm
mV Resolution0.1 mV
pH Range0 to 14
Width 310 mm
pH Resolution0.01 pH
Weight7 kg
Titrator TypePotentiometric
Additional Specifications

Electrode Inputs: Indicator electrode: 1
Reference electrode: 1
Thermistor electrode: 1
KF electrode: 1
Titration steps: Up to three(3) steps
Number of Endpoints: Up to two(2) points
End point detection: Automatic detection by:
-Inflection point
-Set point
-F Cross point
-B Cross point
Display screen: 2-lines by 16 digits with backlit LCD
Display unit: pH, mV, mgH2O, %, ppm, M, g/L, mg/g, Fact1, Fact2
pH calibration: 2 or 3 points (compliant to ASTM or other standard buffers)
File function: 30 files for potentiometric titrations
3 files for Karl-Fischer titrations
10 files for titration control methods
Calculation function: Concentration calculation, Statistics calculation
Memory data capacity: 50 titration results along with titration curves and parameters and via external computer
Precautions against power failure: Built-in backup battery
Electrodes (Standard component): GE-101B Glass electrode
· RE-201 Reference electrode
· TE-401 Thermistor electrode
Buret: Capacity: 20 mL, Minimum drop size: 0.01mL
Reproducibility: within ±0.01 mL
Tubing: Teflon tube of 2 mm(ID) and 3 mm(OD)
Switching Valve: Automatic switching valve with ceramic joint.
Stirrer: Integrated, variable speed, magnetic stirrer
Printers: Optional thermal printer; PR-2000T2(PRINTY3), Optional impact printer; PR-302B(CBM-910-40PF)
External input / output: RS-232C; 2 ports
Port 1 (BALANCE):For connection to electronic balance.
Port 2 (HOST):For connection to external computer.
Power supply / Power consumption AC100 - 240 V, 50/60 Hz, 100 VA
Weight: Approx. 7 kg