Features of CB Series
- Sterilization
- Permadry™ humidity system
- APT.line™ heating technology
- Gas distribution
- Inner chamber concept
- CO2 measurement
- Operating costs
General Specifications
There are no General Specifications available.
Series Modals
BINDER - CB 150
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 722 mm |
Humidity | Humidity (avg. value) (% RH): = 95 |
Height | 919 mm |
Internal Depth | 500 mm |
Internal Height | 600 mm |
Width | 680 mm |
Internal Width | 500 mm |
Power Requirements | Voltage (± 10%) 50/60 Hz (V) : 230 Voltage (± 10%) 60 Hz (V): 115 Nominal power (kW) : 1.3 Energy consumption at 37 °C (98.6 °F) (W) : 100 |
Peak Power | 1300 W |
Chamber Volume | 150 L |
CO2 Sensor | Infrared (IR) |
CO2 Range | 0 to 20 % |
Weight | 107 kg |
O2 Range | 0.2 to 95 % |
Maximum Shelf Load | 10 kg |
O2 Accuracy | 0.1 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | Dimensions of shelf, width x depth (mm): 495 x 444 |
Incubator Orientation | Benchtop |
Additional Model Specifications | Exterior dimensions Depth (plus 54 mm (2.1 inch) for door handle and connection) (mm/inch): 722 / 28.4 Wall clearance side (mm/inch): 50 / 1.97 Wall clearance rear (mm/inch): 100 / 3.94 Number of doors (ea.): 1 Inner glass door(s): 1 Interior dimensions Stainless steel shelf (number standard/max.): 3 / 6 Load per shelf (kg): 10 Permitted total load (kg): 30 Weight (empty) (kg/lbs.): 107 / 236 Temperature data Temperature variation at 37 °C (98.6 °F) (± K): 0.3 Temperature fluctuation (± K): 0.1 Recovery time after door was opened for 30 sec. at 37 °C (min) 1): 3 CO2 data Setting accuracy (Vol.-% CO2): 0.1 Recovery time after doors was opened for 30 sec. at 5 vol. % (min.) 1): 7 Connection hose nozzle for CO2 DN 6 for hose with internal diameter (mm): 6 / 0.24 O2 data Setting accuracy (Vol.-% O2): 0.1 Recovery time after door was opened for 30 sec. (min.) 1): at 1.0 vol. % O2 (min.): 33 at 5.0 vol. % O2 (min.): 10 O2 measurement: ZrO2 Gas connection hose nozzle for O2 / N2 DN 6 for hose with internal diameter (mm/inch): 6 / 0.24 1) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time. |
BINDER - CB 160
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 715 mm |
Humidity | 90-95% |
Height | 920 mm |
Internal Depth | 500 mm |
Internal Height | 600 mm |
Width | 680 mm |
Internal Width | 500 mm |
Power Requirements | 100-120V |
Chamber Volume | 150 L |
CO2 Range | 0 to 20 % |
Weight | 110 kg |
O2 Range | 0.2 to 95 % |
Maximum Shelf Load | 10 kg |
O2 Accuracy | 0.1 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 495 x 444 mm |
Incubator Orientation | Benchtop |
Additional Model Specifications |
BINDER - CB 170
[+] View Model SpecificationsHumidity | 90 to 95 % RH |
Temperature Uniformity | 60 °C |
Height | 1.8 m |
Chamber Volume | 170 L |
CO2 Range | 0 to 20 % |
O2 Range | 0.2 to 20 % |
Incubator Orientation | Floor Standing |
Additional Model Specifications | Alternative O2 control range: 10 to 95 vol% O2 (option for O and GO versions) Tried-and-tested anti-contamination concept with 180 °C hot air sterilization Hot-air sterilizable CO2 sensor with single-beam infrared technology CO2 gas-mixing jet with Venturi effect Intuitive touchscreen controller Internal data recording, can be read out in open format via USB interface DuoDoor™ system: Unit door and glass door can be opened with one handle Lockable door handle Computer interface: Ethernet Zero-voltage alarm contact Tightly sealed inner door made of tempered safety glass Perforated shelves, stainless steel Units are stackable with stacking adapter |
BINDER - CB 210
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 722 mm |
Humidity | Humidity (avg. value) (% RH) : = 95 |
Height | 1069 mm |
Internal Depth | 500 mm |
Internal Height | 750 mm |
Width | 740 mm |
Internal Width | 560 mm |
Power Requirements | Voltage (± 10%) 50 / 60 Hz (V): 230 Voltage (± 10%) 60 Hz (V): 115 Nominal power (kW) : 1.5 Energy consumption at 37 °C (98.6 °F) (W): 130 |
Peak Power | 1500 W |
Chamber Volume | 210 L |
CO2 Sensor | Infrared (IR) |
CO2 Range | 0 to 20 % |
Weight | 121 kg |
O2 Range | 0.2 to 95 % |
Maximum Shelf Load | 10 kg |
O2 Accuracy | 0.1 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | Dimensions of shelf, width x depth (mm): 555.5 x 444 |
Incubator Orientation | Benchtop |
Additional Model Specifications | Exterior dimensions Depth (plus 54 mm (2.1 inch) for door handle and connection) (mm/inch): 722 / 28.4 Wall clearance side (mm/inch): 50 / 2.0 Wall clearance rear (mm/inch): 100 / 3.94 Number of doors (ea.): 1 Inner glass door(s): 1 Interior dimensions Stainless steel shelf (number standard/max.): 3 / 8 Load per shelf (kg/lbs.): 10 / 22.0 Permitted total load (kg/lbs.): 30 / 66.1 Weight (empty) (kg/lbs.): 121 / 267 Temperature data Temperature variation at 37 °C (98.6 °F) (± K): 0.4 Temperature fluctuation (± K) 0.1 Recovery time after door was opened for 30 sec. at 37 °C (min) 1): 3 CO2 data Setting accuracy (Vol.-% CO2): 0,1 Recovery time after door was opened for 30 sec. 1) at 5 vol. % (min.): 9 Connection hose nozzle for CO2 DN 6 for hose with internal diameter (mm/inch): 6 / 0.24 O2 data Setting accuracy (Vol.-% O2): 0.1 Recovery time after door was opened for 30 sec. (min.) 1): at 1.0 vol. % O2 (min.): 54 at 5.0 vol. % O2 (min.): 11 O2 measurement: ZrO2 Gas connection hose nozzle for O2 / N2 DN 6 for hose with internal diameter (mm/inch): 6 / 0.24 1) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time. |
BINDER - CB 220
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 715 mm |
Humidity | 90-95% |
Height | 1070 mm |
Internal Depth | 500 mm |
Internal Height | 750 mm |
Width | 740 mm |
Internal Width | 560 mm |
Power Requirements | 100-120V |
Chamber Volume | 210 L |
CO2 Range | 0 to 20 % |
Weight | 132 kg |
O2 Range | 2 to 95 % |
Maximum Shelf Load | 10 kg |
O2 Accuracy | 0.1 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 555.5 x 444mm |
Incubator Orientation | Floor Standing |
Additional Model Specifications |
BINDER - CB 53
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 545 mm |
Humidity | Humidity (avg. value) (% RH) : = 95 |
Height | 720 mm |
Internal Depth | 332 mm |
Internal Height | 400 mm |
Width | 580 mm |
Internal Width | 400 mm |
Power Requirements | Voltage (± 10%) 50/60 Hz (V) : 230 Voltage (± 10%) 60 Hz (V): 115 Nominal power (kW): 1.0 Energy consumption at 37 °C (98.6 °F) (W) 1): 70 |
Peak Power | 1000 W |
Chamber Volume | 53 L |
CO2 Sensor | Infrared (IR) |
CO2 Range | 0 to 20 % |
Weight | 60 kg |
O2 Range | 0.2 to 95 % |
Maximum Shelf Load | 10 kg |
O2 Accuracy | 0.1 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 396 x 289 mm. |
Incubator Orientation | Floor Standing |
Additional Model Specifications | Exterior dimensions Depth (plus 55 mm (2.2 inch) for door handle and connection) (mm/inch) 545 / 21.5 Wall clearance side (mm/inch): 50 / 1.97 Wall clearance rear (mm/inch): 100 / 3.94 Number of doors (ea.): 1 Inner glass door(s): 1 Interior dimensions Number of shelves (standard/max.): 2 / 3 Load per shelf (kg/lbs.): 10 / 22.0 Permitted total load (kg/lbs.): 30 / 66.1 Weight (empty) (kg/lbs.): 60 / 133 Temperature data Temperature variation at 37 °C (± K): 0.3 Temperature fluctuation at 37 °C (± K): 0.1 Recovery time after door was opened for 30 sec. at 37 °C (98.6 °F) (min.): 3 Humidity data Humidity (avg. value) (% RH): = 95 CO2 data Setting accuracy (Vol.-% CO2): 0.1 Recovery time after door was opened for 30 sec at 5.0 vol. % CO2 (min.): 6 Connection hose nozzle for CO2 for hose with internal diameter (mm/inch): 6 /0.24 O2 data Setting accuracy (Vol.-% O2): 0.1 Recovery time after door was opened for 30 sec at 1.0 vol. % O2 (min.): 25 at 5.0 vol. % O2 (min.): 9 O2 measurement: ZrO2 Connection hose nozzle for O2 / N2 for hose with internal diameter (mm): 6 / 0.24 1) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time. |
BINDER - CB 60
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 545 mm |
Humidity | 90-95% |
Height | 720 mm |
Internal Depth | 330 mm |
Internal Height | 400 mm |
Width | 580 mm |
Internal Width | 400 mm |
Power Requirements | 100-120V |
Chamber Volume | 53 L |
CO2 Range | 0 to 20 % |
Weight | 68 kg |
O2 Range | 0.2 to 95 % |
Maximum Shelf Load | 30 kg |
O2 Accuracy | 0.1 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 396 x 289mm |
Incubator Orientation | Benchtop |
Additional Model Specifications | Hot air sterilization at 180 °C Sterilizable CO2 sensor Unique BINDER technologies (patented air jacket system, controlled condensation, etc.) |
Videos