Amerex Instruments - HV-Series
Manufactured by Amerex Instruments
Portable, top loading autoclaves with advanced and user-friendly features
- Space-saving design with lid opening upward.
- Programmable auto-start for initiating a cycle up to 1 week later.
- Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
- Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
- One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust.
- Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly
- In-process display shows status and progress of sterilization cycle.
- Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
- Unique accessory: Floating sensor to monitor load temperature.
- Sterilization timer is activated only when load temperature reaches set temperature.
Active Questions & AnswersAsk a Question
There are no current Discussions
Autoclaves Service ProvidersView All (25)
Documents & Manuals
There are no Documents or Manuals available.
Features
There are no Features available.
General Specifications
There are no General Specifications available.
Series Modals
Amerex Instruments - HV-110
[+] View Model SpecificationsDepth | 25.6 in |
Height | 46.5 in |
Width | 26 in |
Power Requirements | 208V/220V/240V, 50/60 Hz, single phase |
Orientation | Floor Standing |
Peak Power | 4000 W |
Chamber Volume | 110 L |
Weight | 308 lbs (shipping) |
Additional Model Specifications | TEMPERATURE Display Range: 137ºC Warming Range: 45ºC to 60ºC Agar Dissolution: Heating at 60ºC to 100ºC for up to 1 hour (temp. and time programmable), followed by 45ºC to 60ºC (temp. programmable) for up to 20 hours. GAUGE PRESSURE Operating Range: 3 to 30 psi (gauge), 0.021 to 0.21MPa TIMER Sterilization: 1 to 250 minutes Delayed Auto-start: Program autoclave to start 1 minute to 7 days later SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar: Heating -> Sterilization -> Exhaust (slow, programmable) -> Warming -> Completion 2. For liquids: Heating -> Sterilization -> Exhaust (slow, programmable) -> Completion 3. For solids: Heating -> Sterilization -> Exhaust (fast, programmable) -> Completion 4. For melting agar or for faster start-up: Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion ACCESSORIES Stainless steel: Mesh wire baskets, buckets (pails), and round tube racks Factory or field installed: Floating (load)sensor, auto water supply unit, and digital printer |
Amerex Instruments - HV-25
[+] View Model SpecificationsDepth | 18 |
Height | 37.4 |
Width | 19 |
Power Requirements | 120V, 50/60 Hz (220V/240V available) |
Orientation | Floor Standing |
Peak Power | 1500 W |
Chamber Volume | 25 L |
Weight | 160 lbs (shipping) |
Additional Model Specifications | TEMPERATURE Display Range: 128ºC Warming Range: 45ºC to 60ºC Agar Dissolution: Heating at 60ºC to 100ºC for up to 1 hour (temp. and time programmable), followed by 45ºC to 60ºC (temp. programmable) for up to 20 hours. GAUGE PRESSURE Operating Range: 3 to 22 psi gauge (0.02 to 148 MPa) TIMER Sterilization: 1 to 250 minutes Delayed Auto-start: Program autoclave to start 1 minute to 7 days later SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar: Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion 2. For liquids: Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion 3. For solids: Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion 4. For melting agar or for faster start-up: Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion ACCESSORIES Stainless steel: Mesh wire baskets, buckets (pails), and round tube racks Factory or field installed: Floating sensor, auto water supply unit, and digital printer |
Amerex Instruments - HV-50
[+] View Model SpecificationsDepth | 21 in |
Height | 41 in |
Width | 20 in |
Power Requirements | 120V, 50/60 Hz |
Orientation | Floor Standing |
Peak Power | 2000 W |
Chamber Volume | 50 L |
Weight | 180 lbs (shipping) |
Additional Model Specifications | TEMPERATURE Display Range: 137ºC Warming Range: 45ºC to 60ºC Agar Dissolution: Heating at 60ºC to 100ºC for up to 1 hour (temp. and time programmable), followed by 45ºC to 60ºC (temp. programmable) for up to 20 hours. GAUGE PRESSURE Operating Range: 3 to 30 psi (0.02 to 0.206 MPa) TIMER Sterilization: 1 to 250 minutes Delayed Auto-start: Program autoclave to start 1 minute to 7 days later SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar: Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion 2. For liquids: Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion 3. For solids: Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion 4. For melting agar or for faster start-up: Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion ACCESSORIES Stainless steel: Mesh wire baskets, buckets (pails), and round tube racks Factory or field installed: Floating sensor, auto water supply unit, and digital printer |
Amerex Instruments - HV-85
[+] View Model SpecificationsDepth | 25.6 in |
Height | 39.4 in |
Width | 26 in |
Power Requirements | 208V/220V/240V, 50/60 Hz, single phase |
Orientation | Floor Standing |
Peak Power | 3000 W |
Chamber Volume | 85 L |
Weight | 282 lbs (shipping) |
Additional Model Specifications | TEMPERATURE Display Range: 137ºC Warming Range: 45ºC to 60ºC Agar Dissolution: Heating at 60ºC to 100ºC for up to 1 hour (temp. and time programmable), followed by 45ºC to 60ºC (temp. programmable) for up to 20 hours. GAUGE PRESSURE Operating Range: 3 to 30 psi (gauge), 0.021 to 0.21MPa TIMER Sterilization: 1 to 250 minutes Delayed Auto-start: Program autoclave to start 1 minute to 7 days later SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar: Heating -> Sterilization -> Exhaust (slow, programmable) -> Warming -> Completion 2. For liquids: Heating -> Sterilization -> Exhaust (slow, programmable) -> Completion 3. For solids: Heating -> Sterilization -> Exhaust (fast, programmable) -> Completion 4. For melting agar or for faster start-up: Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion ACCESSORIES Stainless steel: Mesh wire baskets, buckets (pails), and round tube racks Factory or field installed: Floating (load)sensor, auto water supply unit, and digital printer |