Amerex Instruments - HVA-Series
Manufactured by Amerex Instruments
Portable top-loading autoclaves with cooling fan and user-friendly features.
- Space-saving design with lid opening upward.
- Standard built-in cooling fan for faster post- sterilization cooling.
- Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
- Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
- One-touch lever to easily open and close chamber lid.
- Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
- Door-closure sensor prevents a cycle from starting unless the door is closed properly.
- In-process display shows the status and the progress of sterilization cycle.
- HVA-85: 85 liters, 16.5” diameter x 24.2” height
- HVA-110: 110 liters, 16.5” diameter x 31.3” height
Active Questions & AnswersAsk a Question
There are no current Discussions
Autoclaves Service ProvidersView All (24)
Documents & Manuals
There are no Documents or Manuals available.
Features
There are no Features available.
General Specifications
There are no General Specifications available.
Series Modals
Amerex Instruments - HVA-110
[+] View Model SpecificationsDepth | 25.6 in |
Height | 46.4 in |
Chamber Height | 31.3 in |
Width | 26 in |
Power Requirements | 220V±10%, 50/60 Hz, single phase |
Orientation | Floor Standing |
Peak Power | 4000 W |
Chamber Volume | 110 L |
Weight | 308 lbs (shipping) |
Internal Diameter | 16.5 in |
Additional Model Specifications | TEMPERATURE Display Range: 137ºC Agar Warming Range: After sterilization, agar can be maintained from 45ºC to 60ºC (programmable) to prevent coagulation for up to 20 hours. PRESSURE Max. Pressure (Gauge): 0.26MPa Pressure Gauge Range: 0 to 0.40MPa TIMER Sterilization: 1 to 250 minutes SAFETY DEVICES Dual-sensing (temperature and pressure) lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar: Heating -> Sterilization -> Exhaust (choice of no exhaust and two exhaust rates) -> Warming -> Completion 2. For liquids: Heating -> Sterilization -> Exhaust (choice of no exhaust and two exhaust rates)-> Completion 3. For solids: Heating -> Sterilization -> Exhaust (choice of no exhaust or fast) -> Completion ACCESSORIES Stainless steel: Mesh wire baskets, buckets (pails), and tube rack |
Amerex Instruments - HVA-85
[+] View Model SpecificationsDepth | 25.6 in |
Height | 39.4 in |
Chamber Height | 24.2 in |
Width | 26 in |
Power Requirements | 220V±10%, 50/60 Hz, single phase |
Orientation | Floor Standing |
Peak Power | 3000 W |
Chamber Volume | 85 L |
Weight | 282 lbs (shipping) |
Internal Diameter | 16.5 in |
Additional Model Specifications | TEMPERATURE Display Range: 137ºC Agar Warming Range: After sterilization, agar can be maintained from 45ºC to 60ºC (programmable) to prevent coagulation for up to 20 hours. PRESSURE Max. Pressure (Gauge): 0.26MPa Pressure Gauge Range: 0 to 0.40MPa TIMER Sterilization: 1 to 250 minutes SAFETY DEVICES Dual-sensing (temperature and pressure) lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar: Heating -> Sterilization -> Exhaust (choice of no exhaust and two exhaust rates) -> Warming -> Completion 2. For liquids: Heating -> Sterilization -> Exhaust (choice of no exhaust and two exhaust rates)-> Completion 3. For solids: Heating -> Sterilization -> Exhaust (choice of no exhaust or fast) -> Completion ACCESSORIES Stainless steel: Mesh wire baskets, buckets (pails), and tube rack |