PHCBi - MLS-3751L/MLS-3781L
Manufactured by PHCBi
Top-Loading Portable Autoclaves
The importance of sterilization is essential to good laboratory practice, particularly in biotechnology, pharmaceutical and clinical laboratories. Of all sterilization methods, high pressure steam (autoclave) is the most widely used because of its efficacy, speed and reliability. The Panasonic MLS-Series top-loading autoclaves provide a safe, reliable high pressure steam sterilizing environment within a self-contained unit that is easy to use. These reliable, energy saving autoclaves are ideal for a wide range of applications.
Active Questions & AnswersAsk a Question
1Replies
Need Instruction Manual
Recent Questions & Answers
Updated byBritta
Autoclaves Service ProvidersView All (25)
Documents & ManualsView All Documents
Features of MLS-3751L/MLS-3781L
- Microprocessor Controls
- Programmable
- Fail-safe Functions
- Optional Process Printer
- Process Voice Notification
- Compact Design
- Energy Savings Design
- Ergonomic Design
- Low-Profile
- Swing-Top Lid
- Large Chamber Capacity
General Specifications
There are no General Specifications available.
Series Modals
PHCBi - MLS-3751L
[+] View Model SpecificationsChamber Depth | 16.3 in |
Depth | 24.9 in |
Height | 29.4 in |
Width | 18.8 in |
Power Requirements | 115 V, 20 Amp breaker, Requires a NEMA L5-20R Receptacle (Locking Type) |
Orientation | Floor Standing |
Chamber Volume | 50 L |
Weight | 134 lbs |
Internal Diameter | 14.6 in |
Additional Model Specifications | CHAMBER MATERIAL SUS304 (Austenitic stainless steel) STERILIZATION TEMPERATURE RANGE 115ºC - 135ºC CULTURE MEDIUM MELTING TEMPERATURE RANGE 60ºC - 114ºC KEEP WARM TEMPERATURE RANGE 60°C to 114°C TEMPERATURE DISPLAY Microprocessor LED PRESSURE GAUGE RANGE 0.1 - 0.4 MPa MAX TEMPERATURE 135°C STERILIZATION TIMER RANGE 1 min. - 5 hrs; Melting: 1 min - 5 hrs; Heat-rentention: 72 hrs fixed; Timer (1 week - Desgination: Year, month, day hour, and minute) PROGRAM TIMER 1 min to 5 hours/keep warm - 72 hours STERILIZATION TIMER 1 minute to 5 hours MELTING TIMER RANGE 1 minute to 5 hours CASTERS 4 EXHAUST TANK 2 liter polyethylene tank CALIBRATION Electronic ENERGY CONSUMPTION 1.9 kW (120 V only), 2 kW ACCESSORIES Recorder (Optional) |
PHCBi - MLS-3781L
[+] View Model SpecificationsChamber Depth | 24.8 in |
Depth | 24.9 in |
Height | 38 in |
Width | 18.8 in |
Power Requirements | 208-230 V, 30 Amp breaker, Requires a NEMA L6-30R Receptacle (Locking Type) |
Orientation | Floor Standing |
Chamber Volume | 75 L |
Weight | 157 lbs |
Internal Diameter | 14.6 in |
Additional Model Specifications | CHAMBER MATERIAL SUS304 (Austenitic Stainless Steel) STERILIZATION TEMPERATURE RANGE 115ºC - 135ºC CULTURE MEDIUM MELTING TEMPERATURE RANGE 60ºC - 114ºC KEEP WARM TEMPERATURE RANGE 60°C to 114°C TEMPERATURE DISPLAY Microprocessor LED PRESSURE GAUGE RANGE 0.1 - 0.4 MPa MAX TEMPERATURE 135°C STERILIZATION TIMER RANGE 1 min. - 5 hrs; Melting: 1 min - 5 hrs; Heat-rentention: 72 hrs fixed; Timer (1 week - Desgination: Year, month, day hour, and minute) PROGRAM TIMER 1 min to 5 hours/ keep warm - 72°C STERILIZATION TIMER 1 minute to 5 hours MELTING TIMER RANGE 1 minute to 5 hours CASTERS 4 EXHAUST TANK 2 liter polyethylene tank SAFETY FUNCTIONS Relief Pressure 34.8 PSI CALIBRATION Electronic ENERGY CONSUMPTION 4 kW ACCESSORIES Recorder (Optional) |