HANNA instruments - HI 901/902
Complete Analytical Titration Systems Tailor-made to meet your Industry's Standards
HI 902 -Complete Analytical Titration System w/ 2 Burettes
Active Questions & AnswersAsk a Question
Titrators Service ProvidersView All (5)
Documents & ManualsView All Documents
Features of HI 901/902
- 320 x 240 pixel LCD w/backlight.
- Precise dosing system (accuracy under 0.1% of burette volume).
- Support up to 100 titration methods (standard and user defined).
- Clip Lock™ — change burettes quickly with auto burette recognition
- Dynamic/Linear dosing feature.
- Fixed end point potential or pH.
- Equivalence point detection (first derivative and second derivative).
- The results are displayed directly in the selected units.
- Titration graph can by displayed on-screen & saved.
- User customized reports can be printed, saved on floppy disk or transferred to PC via RS232 interface.
- Reminders for titrant age and standardization expiration.
- Self diagnostic features for peripheral devices including pump, valve, burette and stirrer.
General Specifications
Depth | 13.8 in |
Height | 14.9 in |
mV Resolution | 0.1 mV |
Width | 15.3 in |
pH Resolution | Selectable |
Power Requirements | 115 Vac or 230 Vac, 50/60 Hz, fuse-protected |
Weight | 22 lbs (with one pump) |
Titrator Type | Multi-Parameter |
Additional Specifications
Resolution: 0.1°C
Accuracy: ±0.1 mV / ±0.001 pH / ±0.1°C
Burette Capacity: 5 mL (±5 µl), 10 mL (±10 µl), 25 mL (±25 µl) and 50 mL (±50 µl)
with 0.001 mL display resolution
Burette Resolution: 1/40000
Dosing Accuracy: 0.1% of full burette volume
Display: graphic LCD 120 x 90 mm (4.7 x 3.5"); 320 x 240 pixel resolution
Menu Language: English, Italian and Portuguese
Method: 100 (11 standard, 89 user-defined)
Burette Auto Detection: burette size is automatically recognized when inserted into the unit
Programmable Stirrer: propeller type, 100-2500 RPM with 100 rpm resolution
Flow Rate: user-selectable from 0.1 mL/min to 2x vol. burette/min
Temperature Compensation: pH measurements are automatically temperature compensated
pH Calibration: manual or automatic, at 1-5 points with 4 buffer sets for custom buffers
Potentiometric Titrations: Acid/Base (pH or mV mode), Redox, Precipitation, Complexometric, non aqueous, ion-selective, argentometric (in mV mode only)
Titration Methods: fixed mV or pH end-point detection and first equivalency point detection (with the first or second derivative of titration curve)
Real Time Data: mV/volume or pH/volume titration curve, graph of first or second derivatives
Data Storage: up to 100 complete titrations and pH/mV logging complete reports
Disk Drive: Built-in 3.5" floppy disk drive
Periphereals: connections for VGA display, PC-keyboard, parallel printer, RS232 interface
Power Consumption: 40 VA max.
Environment: 10 to 40°C (50 to 104°F); RH max 95%