HANNA instruments - HI 901/902

Manufactured by  HANNA instruments
Follow this Equipment

Complete Analytical Titration Systems Tailor-made to meet your Industry's Standards

HI 901/902 is an automatic titrator from HANNA® that complements our wide range of products dedicated to quick and accurate laboratory analysis. Each unit is provided with numerous features amenable to routine samples analysis. HI 901/902 performs acid/base, potentiometric titrations. This versatile titrator offers a total of 100 methods: 89 of which can be customized. When powered on, the instrument initiates an internal diagnostics check and then readies itself for the first titration of the day. A large LCD screen clearly shows the chosen method, correlated information and also indicates which parameters may be adjusted. A real-time titration curve is shown on the display; this feature is useful when new methods are tested or when a procedure needs to be optimized. At the end of the titration, all data, including the graph, are automatically stored in memory and can be copied to disk via the built-in floppy drive or through direct connection with the serial cable supplied with the titrator. The device is equipped with an RS485 serial port.  
  
HI 902 -Complete Analytical Titration System w/ 2 Burettes
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked byMohamed Salah

avatar placemark

Asked bytom97013

Titrators Service ProvidersView All (5)

Request Support
Features of HI 901/902
  • 320 x 240 pixel LCD w/backlight.  
  • Precise dosing system (accuracy under 0.1% of burette volume).  
  • Support up to 100 titration methods (standard and user defined).  
  • Clip Lock™ — change burettes quickly with auto burette recognition  
  • Dynamic/Linear dosing feature.  
  • Fixed end point potential or pH.  
  • Equivalence point detection (first derivative and second derivative).  
  • The results are displayed directly in the selected units.  
  • Titration graph can by displayed on-screen & saved.  
  • User customized reports can be printed, saved on floppy disk or transferred to PC via   RS232 interface.  
  • Reminders for titrant age and standardization expiration.  
  • Self diagnostic features for peripheral devices including pump, valve, burette and stirrer.
General Specifications
Depth 13.8 in
Height14.9 in
mV Resolution0.1 mV
Width 15.3 in
pH ResolutionSelectable
Power Requirements 115 Vac or 230 Vac, 50/60 Hz, fuse-protected
Weight22 lbs (with one pump)
Titrator TypeMulti-Parameter
Additional Specifications

Resolution: 0.1°C  
Accuracy: ±0.1 mV / ±0.001 pH / ±0.1°C  
Burette Capacity: 5 mL (±5 µl), 10 mL (±10 µl), 25 mL (±25 µl) and 50 mL (±50 µl)  
with 0.001 mL display resolution  
Burette Resolution: 1/40000  
Dosing Accuracy: 0.1% of full burette volume  
Display: graphic LCD 120 x 90 mm (4.7 x 3.5"); 320 x 240 pixel resolution  
Menu Language: English, Italian and Portuguese  
Method: 100 (11 standard, 89 user-defined)  
Burette Auto Detection: burette size is automatically recognized when inserted into the unit  
Programmable Stirrer: propeller type, 100-2500 RPM with 100 rpm resolution  
Flow Rate: user-selectable from 0.1 mL/min to 2x vol. burette/min  
Temperature Compensation: pH measurements are automatically temperature compensated  
pH Calibration: manual or automatic, at 1-5 points with 4 buffer sets for custom buffers  
Potentiometric Titrations: Acid/Base (pH or mV mode), Redox, Precipitation, Complexometric, non aqueous, ion-selective, argentometric (in mV mode only)  
Titration Methods: fixed mV or pH end-point detection and first equivalency point detection (with the first or second derivative of titration curve)  
Real Time Data: mV/volume or pH/volume titration curve, graph of first or second derivatives  
Data Storage: up to 100 complete titrations and pH/mV logging complete reports  
Disk Drive: Built-in 3.5" floppy disk drive  
Periphereals: connections for VGA display, PC-keyboard, parallel printer, RS232 interface  
Power Consumption: 40 VA max.  
Environment: 10 to 40°C (50 to 104°F); RH max 95%