Netzsch - TG 209 F1 Iris®
Manufactured by Netzsch
The vacuum-tight thermo-microbalance for highest demands
The new TG 209 F1 Iris® unites extreme flexibility and outstanding performance in one instrument.
The TG 209 F1 Iris® offers a platform identical to that of the DSC 204 F1 Phoenix®, together comprising an instrument generation that stands out due to unique design and revolutionary flexibility.
The thermo-microbalance operates in a temperature range between 10°C (thermostat cooling) and 1000°C with freely selectable heating rates from 0.001 K/min up to 100 K/min. The exact sample temperature is detected by a thermocouple in direct contact with the crucible.
The vacuum-tight, upright assembly and the integrated mass flow controllers for the purge and protection gases create ideal conditions for coupling to an FTIR or MS for gas analysis - even with an installed automatic sample changer (ASC) for up to 64 sample crucibles.
The TG 209 F1 Iris® Has Been Replaced By The TG 209 F1 Libra®
The TG 209 F1 Iris® offers a platform identical to that of the DSC 204 F1 Phoenix®, together comprising an instrument generation that stands out due to unique design and revolutionary flexibility.
The thermo-microbalance operates in a temperature range between 10°C (thermostat cooling) and 1000°C with freely selectable heating rates from 0.001 K/min up to 100 K/min. The exact sample temperature is detected by a thermocouple in direct contact with the crucible.
The vacuum-tight, upright assembly and the integrated mass flow controllers for the purge and protection gases create ideal conditions for coupling to an FTIR or MS for gas analysis - even with an installed automatic sample changer (ASC) for up to 64 sample crucibles.
The TG 209 F1 Iris® Has Been Replaced By The TG 209 F1 Libra®
Active Questions & AnswersAsk a Question
Need Equipment Support?
Documents & ManualsView All Documents
Features of TG 209 F1 Iris®
- Mass changes in % or mg
- Automatic evaluation of mass changing steps
- Determination of mass-/ temperature pair of variates
- Determination of the residual mass
- Extrapolated onset and endset
- Peak temperatures of the 1st and 2nd derivate of the mass changing curve
- Automatic baseline- and buoyancy-correction
- c-DTA® for the calculated DTA signal with evaluation of characteristic temperatures and peak area (option)
- Super-Res® for automatic rate controlled mass change and high resolution temperature programs (option)
- Sectoral software solutions for conformity, e.g. to GLP, GMP 21 CFR, Part 11
General Specifications
There are no General Specifications available.
Videos
TG 209 F1 Iris®