Agilent Technologies - 1260 Infinity Standard Autosampler

Manufactured by  Agilent Technologies
Follow this Equipment

Reliability and Ease of Use

The Agilent 1260 Infinity Standard Autosampler is designed for the reliability, safety, and ease-of-use needed in pharmaceutical routine tasks and quality control, as well as for environmental and food analyses. It can be upgraded from non-thermostatted version to thermostatted version by adding the Agilent 1290 Infinity Thermostat.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Updated byBob Kafato

Autosamplers Service ProvidersView All (1)

Request Support
Features of 1260 Infinity Standard Autosampler
  • Reliable injections from 0.1 µL to 100 µL.  
  • Easy adaption for injection volumes up to 1500 µL for applications ranging from microbore to semipreparative chromatography.  
  • Low internal volume of 300 µL for the minimum contribution to a system's total internal volume can be even further reduced using "by-pass" mode.  
  • Overlapped injections for increased productivity.  
  • Peltier temperature control from 4 to 40 °C for up to 100 2-mL vials containing thermally labile samples (upgrade from non-thermostatted to thermostatted version possible.
General Specifications
Cross Contamination0.1 % with external needle cleaning
Maximum Pressure8702 psi
Number of Samples100 × 2-ml vials in 1 tray, 40 × 2-ml vials in ½ tray, 15 × 6-ml vials in ½ tray
Standard Injection Range0.1 to 100 μL
Additional Specifications

Valid with standard 100 µL metering head installed  
Injection range:  
Precision:  
<0.25% RSD from 5-100 µL, <1% from 1-5 µL, variable volume  
Sample viscosity range:  
0.2 - 5 cp  
Sample capacity:  
100 × 2-ml vials in 1 tray  
40 × 2-ml vials in ½ tray  
15 × 6-ml vials in ½ tray (Agilent vials only)  
Injection cycle time:  
Typically 50 s depending on draw speed and injection volume  
  
Valid with standard 900 µL metering head installed  
Injection range:  
0.1 - 900 µL in 0.1 µL increments (recommended 1 µL increments)  
Up to 1800 µL with multiple draw (hardware modification required)  
Precision:  
Typically < 0.5 % RSD of peak areas from 5 - 2000 µL  
Typically < 1 % RSD of peak areas from 2000 - 5000 µL  
Typically < 3 % RSD of peak areas from 1 - 5 µL  
Variable volume  
Sample viscosity range:  
0.2 - 5 cp  
Sample capacity:  
100 × 2-ml vials in 1 tray  
40 × 2-ml vials in ½ tray  
15 × 6-ml vials in ½ tray (Agilent vials only)  
Injection cycle time:  
Typically 50 s depending on draw speed and injection volume  
Carryover:  
Typically < 0.1 %, < 0.05 % with external needle cleaning  
Pressure operating range:  
Up to 200 bar (20 MPa or 2901 psi)