Features of KBF series
- Temperature range: 0 °C to 70 °C * Humidity range: 10 % to 80 % RH * APT.line™ preheating chamber technology * Humidity regulation with capacitive humidity sensor and vapor humidification * Inner chamber made of stainless steel * Controller with time-segment programming * Tightly-sealed inner door made of tempered safety glass * 2 stainless steel racks * Access port with silicone plug, 30 mm, left * 4 stable castors, two with brakes, from 240 liters * Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm * Computer interface: Ethernet * Door heating
General Specifications
There are no General Specifications available.
Series Modals
BINDER - KBF 1020
[+] View Model SpecificationsDepth | 1145 mm |
Height | 1925 mm |
Width | 1250 mm |
Weight | 365 kg |
Additional Model Specifications | Internal Dimensions Width [mm]: 976 Height [mm]: 1250 Depth [mm]: 836 Wall clearance sidewise [mm] 100 Wall clearance back [mm] 100 Energy consumption at 40 °C and 75 % RH 650 Wh/h Sound-pressure level [dB(A)] 56 Number of shelves (standard/maximum) 2/15 |
BINDER - KBF 115
[+] View Model SpecificationsDepth | 647 mm (incl. door handle, I-triangle, connection 52 mm) |
Height | 1048 mm |
Width | 880 mm |
Weight | 129 kg |
Additional Model Specifications | Interior dimensions Width (mm): 600 Height (mm): 482 Depth (mm): 351 Interior volume (l): 101 Racks (number standard/max.): 2 / 5 Load per rack (kg): 30 Permitted total load (kg): 100 Temperature data (without humidity) Temperature range (°C) 1): 0 - 70 Temperature variation at 25 °C (± K): 0,2 Temperature variation at 40 °C (± K):0,2 Temperature fluctuation (± K): 0,2 Max. heat compensation up to 40 °C (W): 200 Climate data (with humidity) Temperature range (°C): 10 - 70 Temperature variation: at 25 °C / 60% RH (± K): 0,2 at 40 °C / 75% RH (± K): 0,2 Temperature fluctuation: at 25 °C / 60% RH (± K): 0,1 at 40 °C / 75% RH (± K): 0,1 Humidity range (% RH): 10 - 80 Humidity fluctuation: at 25 °C / 60% RH (± % RH): 2 at 40 °C / 75% RH (± % RH): 2 Recovery time after door was opened for 30 sec: at 25 °C / 60% RH (min.): 15 at 40 °C / 75% RH (min.): 8 Electrical data Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power (kW): 2,0 Energy consumption 40 °C / 75% RH (kW) 1): 0,47 Noise level approx. (dB (A)): 52 |
BINDER - KBF 240
[+] View Model SpecificationsDepth | 800 mm (incl. door handle, I-triangle, connection 50 mm) |
Height | 1460 mm (incl. casters) |
Width | 925 mm |
Weight | 184 kg |
Additional Model Specifications | Interior dimensions Width (mm): 650 Height (mm): 785 Depth (mm): 485 Interior volume (l): 247 Racks (number standard/max.): 2 / 9 Load per rack (kg): 30 Permitted total load (kg): 100 Temperature data (without humidity) Temperature range (°C) 1): 0 - 70 Temperature variation at 25 °C (± K): 0,2 Temperature variation at 40 °C (± K):0,3 Temperature fluctuation (± K): 0,1 Max. heat compensation up to 40 °C (W): 300 Climate data (with humidity) Temperature range (°C): 10 - 70 Temperature variation: at 25 °C / 60% RH (± K): 0,3 at 40 °C / 75% RH (± K): 0,3 Temperature fluctuation: at 25 °C / 60% RH (± K): 0,1 at 40 °C / 75% RH (± K): 0,1 Humidity range (% RH): 10 - 80 Humidity fluctuation: at 25 °C / 60% RH (± % RH): 1,5 at 40 °C / 75% RH (± % RH): 1,5 Recovery time after door was opened for 30 sec: at 25 °C / 60% RH (min.): 4 at 40 °C / 75% RH (min.): 5 Electrical data Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power (kW): 2,1 Energy consumption 40 °C / 75% RH (kW) 1): 0,65 Noise level approx. (dB (A)): 52 |
BINDER - KBF 720
[+] View Model SpecificationsDepth | 887 mm (plus door handle, I-panel, connection 52 mm) |
Height | 1924 mm (incl. casters) |
Width | 1249 mm |
Weight | 309 kg |
Additional Model Specifications | Interior dimensions Width (mm): 970 Height (mm): 1250 Depth (mm): 576 Interior volume (l): 698 Racks (number standard/max.): 2 / 15 Load per rack (kg): 45 Permitted total load (kg): 150 Temperature data (without humidity) Temperature range (°C) 1): 0 - 70 Temperature variation at 25 °C (± K): 0,2 Temperature variation at 40 °C (± K):0,2 Temperature fluctuation (± K): 0,1 Max. heat compensation up to 40 °C (W): 600 Climate data (with humidity) Temperature range (°C): 10 - 70 Temperature variation: at 25 °C / 60% RH (± K): 0,2 at 40 °C / 75% RH (± K): 0,2 Temperature fluctuation: at 25 °C / 60% RH (± K): 0,1 at 40 °C / 75% RH (± K): 0,1 Humidity range (% RH): 10 - 80 Humidity fluctuation: at 25 °C / 60% RH (± % RH): 1,5 at 40 °C / 75% RH (± % RH): 1,5 Recovery time after door was opened for 30 sec: at 25 °C / 60% RH (min.): 2 at 40 °C / 75% RH (min.): 6 Electrical data Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power (kW): 3,1 Energy consumption 40 °C / 75% RH (kW) 1): 0,62 Noise level approx. (dB (A)): 53 |