LI-COR - Odyssey® Fc

Manufactured by  LI-COR
Follow this Equipment

Odyssey Fc Imaging System

The Odyssey Fc Imager is the first CCD imager that offers excellent infrared (IR) fluorescent and chemiluminescent imaging performance in one system. The Odyssey Fc optical system combines solid-state laser diodes at 685 and 785 nm with a low-noise, CCD camera for detection of IR and chemiluminescent signals.

Chemiluminescence detection is simplified with the Odyssey Fc Imaging System. Film and darkroom steps are eliminated, along with the hazardous waste and excessive water usage of film development.

FieldBrite™ XT technology acquires images over the full dynamic range every time, with minimal user adjustments. With the proprietary technologies of the Odyssey Fc Imaging System, a single instrument can perform quantitative IR fluorescent detection PLUS qualitative chemiluminescent detection. Publication-quality images are easy to produce with either detection method. (Because chemiluminescence is a time-dependent enzymatic reaction, its quantitative range is limited. IR fluorescence is superior for quantification.)

The Odyssey Fc Imaging System includes LI-COR Image Studio Software for fast, easy image acquisition and analysis. At the push of a button, targets of interest can be imaged over more than six logs of linear dynamic range in every acquisition.
Active Questions & AnswersAsk a Question

Need Equipment Support?

Request Support
Features of Odyssey® Fc

Wide Linear Dynamic Range Accurately detect strong and weak signals over a broad linear dynamic range.

Two-Color Detection and Quantification Detect two targets simultaneously on the same membrane increases the accuracy of quantification and comparison.

High Sensitivity Near-infrared fluorescence provides sensitivity equal or better than chemiluminescence giving you low background, high signal-to-noise, multiplexed detection, and the sensitivity of any fluorescent system.

Image Studio Software User-friendly software with easy navigation makes acquisition and analysis straight-forward.

Direct Detection for Better Data and a Cleaner Planet No film or darkroom needed. IRDye signals on membranes are stable indefinitely if stored properly.

Flexible System with Many Applications The Odyssey Fc system has been used for many applications, including Western blot analysis, EMSA, In-Gel Westerns, Coomassie gel documentation and DNA gel documentation.

General Specifications
Depth 18.5 in
Height26.5 in
Width 16.3 in
Weight60 lbs
Additional Specifications

Image Field Size: 10 cm x 12 cm
Dynamic Range: 22 bit (>6 logs)
Depth of Field for Best Sample Focus: 6 mm
Patented FieldBrite™ XT Technology: CV <3%
Laser Lifetime: 20,000 hours
700 Channel Laser Source: Solid-state Laser Diode at 685 nm
800 Channel Laser Source: Solid-state Laser Diode at 785 nm
Detectors: Low-noise CCD. Thermoelectrically cooled.

Acquisition Times
Fluorescence (700 and 800 nm) channels: 30 s, 2 min, 10 min plus variable time feature
Chemiluminescence channel: 30 s, 2 min, 10 min, 60 min plus variable time adjustment feature

Focusing: None needed
Operating Conditions: 15-35°C and dewpoint no greater than 22°C, non-condensing
Power Requirements: Universal input between 100-127 VAC (4 Amp) and 200-240 VAC (2 Amp); 50-60 Hz. Voltage fluctuations not to exceed 10% of the nominal voltage. Insulation Category II.
Sensitivity: Similar to industry-leading Odyssey® system.

Videos
  • Infrared Fluorescence and Chemiluminescence for Western Blots in One System

Looking for

LI-COR - Odyssey® Fc?

Shop on LabX.com