LI-COR - Odyssey® Sa

Manufactured by  LI-COR
Follow this Equipment

The Odyssey® Sa Infrared Imaging System Quantitative Westerns and ICW Analysis using a convenient plate reading format

The Odyssey Sa Infrared Imaging System offers the advantages of infrared imaging and the flexibility to handle both plate-based assays and quantitative Western Blots. For walk-away automation with plate-based assays, the Odyssey Sa can be configured to work with a 30- or 50-plate automated stacking system.  
  
The Odyssey Sa also accepts individual membranes or gels providing an affordable solution for labs doing quantitative Western blots and In Cell Western analysis.  
  
The Odyssey Sa Imager has the same two-channel infrared detection specifications as the more versatile Odyssey Infrared Imager. It yields the same excellent sensitivity (1-5 pg with purified transferrin) and broad dynamic range (4-5 logs). The Odyssey Sa Imager is compatible with the BioTek® BioStack™ Automated Microplate Stacking System (either 30-plate or 50-plate configurations) when installed with the Odyssey Sa Express Software for automated plate readout.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Features of Odyssey® Sa
Quantitative Westerns   Infrared detection gives you true quantitative analysis and wide   linear dynamic range (4-5 logs) that chemiluminescence cannot      Multiplex Detection   Quantitative Westerns with two-color scanning for simultaneous detection of   two protein targets or the use of one channel for normalization      High Sensitivity   Detection down to picogram levels, comparable to the industry-leading   Odyssey® Infrared Imaging System      Direct Detection   No film, darkroom, or messy substrates      Clear Data   No loss of weak bands due to overexposed bands. 20-500 µm resolution imaging      Ease of Use   Spot finding, intensity measurements and percent response calculations for   In-Cell Western™ assay analysis
General Specifications
Depth 22 in
Height14 in
Width 18 in
Weight56 lbs
Additional Specifications

[u]Laser/Microscope[/u]  
Laser Lifetime: 40,000 working hours typical  
700 Channel Laser Source: Solid-state diode laser at 685 nm  
800 Channel Laser Source: Solid-state diode laser at 785 nm  
Detectors: Silicon avalanche photodiodes  
Scanning Speed: 6 minutes with 100 µm resolution  
Resolution: 20 - 500 µm  
Focusing Range: 0 - 3.95 mm (suitable for focusing through the bottom of compatible microplates with transparent, flat-bottom wells.)  
  
[u]Operation Specifications[/u]  
Operating Conditions: 15-35° C and dew point no greater than 20° C  
Power Requirements: Automatic voltage selection at 90-250 VAC and 47-63 Hz; 1.1 Amps at 120 V; 200 W maximum  
Data Storage Capacity: Internal hard drive (files also stored on computer)

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com