Thermo Scientific - Heratherm
Heratherm* Microbiological Incubators
Successful incubation is dependent upon the environmental conditions. As such, you need to trust that your valuable samples are maintained in a safe and efficient manner. Thermo Scientific Heratherm microbiological incubators are designed to provide long-term performance with optimal conditions - and are backed by a two-year warranty on parts and labor, meaning confidence for your investment.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
General Purpose Incubator Service ProvidersView All (28)
Documents & ManualsView All Documents
Features of Heratherm
SAFE
- Safe view of samples through internal glass door, without impact on temperature
- Safe conditions with superior temperature uniformity
- Safe containment with automatic overtemperature alarm
- Alarm in case of temperature deviations
EASY
- Easy temperature setting with intuitive user interface
- Easy to remove “One Click” – shelf system
- Easy to clean interior with rounded corners
- Easy to read large display
EFFICIENT
- Efficient small footprint to optimize benchtop space
- Conveniently stackable without the need for tools or stacking kits
- Efficient utilization of interior with flexible shelf system
General Specifications
There are no General Specifications available.
Series Modals
Thermo Scientific - Advanced Protocol IMH100
[+] View Model SpecificationsDepth | 22.2 in |
Height | 32.3 in |
Width | 25.2 in |
Weight | 123 lbs |
Additional Model Specifications | Convection technology: Dual convection Temperature range: ambient +5 °C to 105 °C Spatial temperature deviation* at 37 °C: ± 0.6/± 0.3 °C Temperature deviation over time at 37 °C: ± 0.1 °C Footprint sqm/sqft: 0.36/3.9 Chamber volume L/cuft: 104/3.67 Interior Dimensions, mm/in (W x H x D): 464 x 608 x 368 / 18.3 x 23.9 x 14.5 Number of shelves supplied/max: 2/16 Max. shelf load kg/lb: 25/55 Rated voltage/frequency V/Hz: 120/60 Rated power/max. current W/A: 840/7 |
Thermo Scientific - Advanced Protocol IMH180
[+] View Model SpecificationsDepth | 29.1 in |
Height | 36.2 in |
Width | 25.2 in |
Weight | 154 lbs |
Additional Model Specifications | Convection technology: Dual convection Temperature range: ambient +5 °C to 105 °C Spatial temperature deviation* at 37 °C: ± 0.6/± 0.4 °C Temperature deviation over time at 37 °C: ± 0.1 °C Footprint sqm/sqft: 0.47/5.1 Chamber volume L/cuft: 178/6.3 Interior Dimensions, mm/in (W x H x D): 464 x 708 x 543 / 18.3 x 27.9 x 21.4 Number of shelves supplied/max: 2/19 Max. shelf load kg/lb: 25/55 Rated voltage/frequency V/Hz: 120/60 Rated power/max. current W/A: 1020/8.5 |
Thermo Scientific - Advanced Protocol IMH60
[+] View Model SpecificationsDepth | 22.2 in |
Height | 28.3 in |
Width | 20.9 in |
Weight | 99 lbs |
Additional Model Specifications | Convection technology: Dual convection Temperature range: ambient +5 °C to 105 °C Spatial temperature deviation* at 37 °C: ± 0.6/± 0.2 °C Temperature deviation over time at 37 °C: ± 0.1 °C Footprint sqm/sqft: 0.3/3.2 Chamber volume L/cuft: 66/2.3 Interior Dimensions, mm/in (W x H x D): 354 x 508 x 368/13.9 x 20.0 x 14.5 Number of shelves supplied/max: 2/13 Max. shelf load kg/lb: 25/55 Rated voltage/frequency V/Hz: 120/60 Rated power/max. current W/A: 600/5 |
Thermo Scientific - Advanced Protocol Security IMH100-S
[+] View Model SpecificationsDepth | 22.2 in |
Height | 32.3 in |
Width | 25.2 in |
Weight | 123 lbs |
Additional Model Specifications | Convection technology: Dual convection Temperature range: ambient +5 °C to 105 °C Spatial temperature deviation* at 37 °C: ± 0.6/± 0.3 °C Temperature deviation over time at 37 °C: ± 0.1 °C Footprint sqm/sqft: 0.36/3.9 Chamber volume L/cuft: 104/3.67 Interior Dimensions, mm/in (W x H x D): 464 x 608 x 368 / 18.3 x 23.9 x 14.5 Number of shelves supplied/max: 2/16 Max. shelf load kg/lb: 25/55 Rated voltage/frequency V/Hz: 120/60 Rated power/max. current W/A: 1390 / 11.6 |
Thermo Scientific - Advanced Protocol Security IMH180-S
[+] View Model SpecificationsDepth | 29.1 in |
Height | 36.2 in |
Width | 25.2 in |
Weight | 154 lbs |
Additional Model Specifications | Convection technology: Dual convection Temperature range: ambient +5 °C to 105 °C Spatial temperature deviation* at 37 °C: ± 0.6/± 0.4 °C Temperature deviation over time at 37 °C: ± 0.1 °C Footprint sqm/sqft: 0.47 / 5.1 Chamber volume L/cuft: 178 / 6.3 Interior Dimensions, mm/in (W x H x D): 464 x 708 x 543 / 18.3 x 27.9 x 21.4 Number of shelves supplied/max: 2/19 Max. shelf load kg/lb: 25/55 Rated voltage/frequency V/Hz: 120/60 Rated power/max. current W/A: 1390 / 11.6 |
Thermo Scientific - Advanced Protocol Security IMH60-S
[+] View Model SpecificationsDepth | 22.2 in |
Height | 28.3 in |
Width | 20.9 in |
Weight | 99 lbs |
Additional Model Specifications | Convection technology: Dual convection Temperature range: ambient +5 °C to 105 °C Spatial temperature deviation* at 37 °C: ± 0.6/± 0.2 °C Temperature deviation over time at 37 °C: ± 0.1 °C Footprint sqm/sqft: 0.3/3.2 Chamber volume L/cuft: 66/2.3 Interior Dimensions, mm/in (W x H x D): 354 x 508 x 368/13.9 x 20.0 x 14.5 Number of shelves supplied/max: 2/13 Max. shelf load kg/lb: 25/55 Rated voltage/frequency V/Hz: 120/60 Rated power/max. current W/A: 1390 / 11.6 |
Thermo Scientific - Compact IMC18
[+] View Model SpecificationsDepth | 18.5 in |
Height | 16.3 in |
Width | 10.2 in |
Weight | 15.9 lbs |
Additional Model Specifications | Convection technology: Mechanical convection Temperature range °C: 17-40 Spatial temperature deviation at 37 °C: ± 1.2 °C Temperature deviation over time at 37 °C: ± 0.2 °C Footprint sqm/sqft: 0.12 / 1.3 Chamber volume L/cuft approx.: 18 / 0.65 Dimensions chamber, mm/in (W x H x D): 180 x 310 x 290 / 7.1 x 12.2 x 11.4 Number of shelves supplied/max: 2 / 3 Max. shelf load kg/lb: 2 / 4.4 Rated voltage/frequency V/Hz: 100-240 / 50/60 Rated power/max. current W/A: 45 / 0.45 - 0.85 |
Thermo Scientific - General Protocol IGS100
[+] View Model SpecificationsDepth | 22.2 in |
Height | 32.3 in |
Width | 25.2 in |
Additional Model Specifications | Chamber Volume: 117L (4.0 cu. ft.) Footprint: 0.36 sq. m (3.9 sq. ft.) Interior D x W x H: 16.3 x 18.3 x 23.9 in. No. of Shelves Supplied: 2 Max. No. of Shelves: 16 Rated Power; Max. Amp.: 540w; 4.5A Convection Technology: Gravity convection Controller: Microprocessor control with vacuum fluorescent display Temperature Range: ambient +5° to 75°C Temperature Uniformity at 37°C: ±0.6°C Temperature Stability at 37°C: ±0.2°C Max. Shelf Load: 25kg (55 lbs.) Rated voltage / frequency: 120V; 60Hz Plug Type: Nema 5-15 |
Thermo Scientific - General Protocol IGS180
[+] View Model SpecificationsDepth | 29.1 in |
Height | 36.2 in |
Width | 25.2 in |
Additional Model Specifications | Chamber Volume: 194L (6.85 cu. ft.) Footprint: 0.47 sq. m (5.1 sq. ft.) Interior D x W x H: 23.2 x 18.3 x 27.9 in. No. of Shelves Supplied: 2 Max. No. of Shelves: 19 Rated Power; Max. Amp.: 720w; 6A Convection Technology: Gravity convection Controller: Microprocessor control with vacuum fluorescent display Temperature Range: ambient +5° to 75°C Temperature Uniformity at 37°C: ±0.6°C Temperature Stability at 37°C: ±0.2°C Max. Shelf Load: 25kg (55 lbs.) Rated voltage / frequency: 120V; 60Hz Plug Type: Nema 5-15 |
Thermo Scientific - General Protocol IGS60
[+] View Model SpecificationsDepth | 22.2 in |
Height | 28.3 in |
Width | 20.9 in |
Additional Model Specifications | Chamber Volume: 75L (2.6 cu. ft.) Footprint: 0.3 sq. m (3.2 sq. ft.) Interior D x W x H: 16.3 x 13.9 x 20.0 in. No. of Shelves Supplied: 2 Max. No. of Shelves: 13 Rated Power; Max. Amp.: 300w; 2.5A Convection Technology: Gravity convection Controller: Microprocessor control with vacuum fluorescent display Temperature Range: ambient +5° to 75°C Temperature Uniformity at 37°C: ±0.6°C Temperature Stability at 37°C: ±0.2°C Max. Shelf Load: 25kg (55 lbs.) Rated voltage / frequency: 120V; 60Hz Plug Type: Nema 5-15 |
Videos
Heratherm* Microbiological Incubators