Labconco - Protector Combination Glove Boxes
Manufactured by Labconco
Protector Combination Glove Boxes provide an enclosed environment for handling both hazardous substances and atmosphere-sensitive materials.
Protector Combination Glove Boxes provide an enclosed environment for handling both hazardous substances and atmosphere-sensitive materials. These glove boxes have a HEPA inlet filter to provide a particulate-free internal environment. Closure of two internal valves converts the box to a controlled atmosphere glove box that can be pressurized up to ±5 inches water gauge achieving a leak-tight inert atmosphere. When atmosphere-sensitive procedures are complete, opening the two internal valves allows air from inside the box to pass through a HEPA outlet filter and optional second HEPA or carbon outlet filter before exhausting via ductwork to the outside. The physical barrier and filtration system of these boxes protect the user from exposure to hazardous materials.
Active Questions & AnswersAsk a Question
There are no current Discussions
Glove Boxes Service ProvidersView All (2)
Documents & ManualsView All Documents
Features of Protector Combination Glove Boxes
- Two internal valves open and close to convert the glove box from a flow-through filtered box to a leak-tight inert atmosphere box.
- Laminated safety glass viewing window with one-piece, molded neoprene gasket seal
- One-piece molded neoprene gasket seals the glass to the liner and provides a leak-tight interior atmosphere.
- Two interior electrical receptacles separately controlled by individual switches on the front panel
- Neoprene gloves, size 9 3/4", are included.
- Comfortable, 8" diameter glove ports
- 30-watt fluorescent lamp provides interior lighting.
- Epoxy-coated steel exterior
- Large transfer chamber allows easy transfer of materials between the laboratory and box while maintaining an established glove box environment.
- Space-saving inner and outer transfer chamber doors
- High efficiency polyester prefilter lengthens the life of the inlet HEPA filter by trapping large particles.
- Inlet and outlet HEPA filter, 99.99% efficient on particulates 0.3 micron in diameter, prevent contaminants from entering or leaving the glove box chamber.
- Built-in blower permits the box's interior atmosphere to be vented to the outside.
- 3” square collar allows connection to ducting system.
- Blower speed control allows the operator to adjust the speed of the built-in blower to vary the volume of airflow through the glove box while varying the internal negative pressure.
- Pressure gauges on the control panel enable the operator to constantly monitor pressures in the glove box and transfer chamber. When internal valves are open, the glove box pressure gauge also indicates HEPA filter loading.
- Control switches for the fluorescent lamp and interior electrical receptacles are conveniently located on the control panel.
- Easy access circuit breakers, located on the back of the box, provide over-current protection to the interior and exterior outlet circuits.
- Pressure relief bubbler helps protect against accidental over- or under-pressurization.
- Factory-tested with a helium mass spectrometer while pressurized with helium at 5" water gauge.
- Exterior electrical outlet for connection of accessory vacuum pump
- Four convenient manual valves control the gas input and exhaust of both the glove box and transfer chamber.
- ETL listed (115 volt models)
- CE Conformity (230 volt models)
General Specifications
There are no General Specifications available.
Series Modals
Labconco - 50600009158
[+] View Model Specifications| Depth | 37.6 in |
| Height | 46.4 in |
| Width | 62.4 in |
| Internal Width | 35.5 in |
| Power Requirements | 115 volts, 60 Hz, 20 amps |
| Number of Glove Ports | 2 |
| Glove Box Construction | Fiberglass |
| Glove Box Type | Stand Alone |
| Ducting | Ductless |
| Additional Model Specifications | [u]Protector Fiberglass Combination Glove Box[/u]
Filter Type: HEPA Primary Application: Work with both atmosphere-sensitive and/or hazardous materials Electrical Requirements: Domestic Power Cord & Plug: 115 volts, 20 amps Required Accessories: supporting base Built-In Options: None Interior-mounted electrical outlets: 115 volt, 6 amp maximum combined rating Exterior back mounted electrical outlet: 115 volt, 9 amp NOTE: Also available with "International Electrical Requirements" |
Labconco - 50601009158
[+] View Model Specifications| Depth | 37.6 in |
| Height | 46.4 in |
| Width | 62.4 in |
| Internal Width | 35.5 in |
| Power Requirements | 115 volts, 60 Hz, 20 amps |
| Number of Glove Ports | 2 |
| Glove Box Construction | Stainless Steel |
| Glove Box Type | Stand Alone |
| Ducting | Ductless |
| Additional Model Specifications | [u]Protector Stainless Steel Combination Glove Box[/u]
Filter Type: HEPA Primary Application: Work with both atmosphere-sensitive and/or hazardous materials Electrical Requirements: Domestic Power Cord & Plug: 115 volts, 20 amps Required Accessories: supporting base Built-In Options: None Interior-mounted electrical outlets: 115 volt, 6 amp maximum combined rating Exterior back mounted electrical outlet: 115 volt, 9 amp NOTE: Also available with "International Electrical Requirements" |
Labconco - 50700009158
[+] View Model Specifications| Depth | 37.6 in |
| Height | 46.4 in |
| Width | 62.4 in |
| Internal Width | 33.5 in |
| Power Requirements | 115 volts, 60 Hz, 20 amps |
| Number of Glove Ports | 2 |
| Glove Box Construction | Fiberglass |
| Glove Box Type | Stand Alone |
| Ducting | Ductless |
| Additional Model Specifications | [u]Protector Fiberglass Combination Glove Box with Pressure Control Module and Foot Pedal[/u]
Filter Type: HEPA Primary Application: Work with both atmosphere-sensitive and/or hazardous materials Electrical Requirements: Domestic Power Cord & Plug: 115 volts, 20 amps Required Accessories: supporting base Built-In Options: Pressure control module and foot pedal Compliance: ETL Interior-mounted electrical outlets: 115 volt, 6 amp maximum combined rating Exterior back mounted electrical outlet: 115 volt, 9 amp NOTE: Also available with "International Electrical Requirements" |
Labconco - 50701009158
[+] View Model Specifications| Depth | 37.6 in |
| Height | 46.4 in |
| Width | 62.4 in |
| Internal Width | 35.5 in |
| Power Requirements | 115 volts, 60 Hz, 20 amps |
| Number of Glove Ports | 2 |
| Glove Box Construction | Stainless Steel |
| Glove Box Type | Stand Alone |
| Ducting | Ductless |
| Additional Model Specifications | [u]Protector Stainless Steel Combination Glove Box with Pressure Control Module and Foot Pedal[/u]
Filter Type: HEPA Primary Application: Work with both atmosphere-sensitive and/or hazardous materials Electrical Requirements: Domestic Power Cord & Plug: 115 volts, 20 amps Required Accessories: supporting base Built-In Options: Pressure control module and foot pedal Compliance: ETL Interior-mounted electrical outlets: 115 volt, 6 amp maximum combined rating Exterior back mounted electrical outlet: 115 volt, 9 amp NOTE: Also available with "International Electrical Requirements" |
Labconco - 50800009158
[+] View Model Specifications| Depth | 37.6 in |
| Height | 46.4 in |
| Width | 62.4 in |
| Internal Width | 35.5 in |
| Power Requirements | 115 volts, 60 Hz, 20 amps |
| Number of Glove Ports | 2 |
| Glove Box Construction | Fiberglass |
| Glove Box Type | Stand Alone |
| Ducting | Ductless |
| Additional Model Specifications | [u]Protector Fiberglass Combination Glove Box with Pressure Control Module, Auto Purge/Fill Sequencer and Foot Pedal[/u]
Primary Application: Work with both atmosphere-sensitive and/or hazardous materials Electrical Requirements: Domestic Power Cord & Plug: 115 volts, 20 amps Required Accessories: supporting base Built-In Options: Pressure control module, foot pedal and purge/fill control module Interior-mounted electrical outlets: 115 volt, 6 amp maximum combined rating Exterior back mounted electrical outlet: 115 volt, 9 amp NOTE: Also available with "International Electrical Requirements" |
Labconco - 50801009158
[+] View Model Specifications| Depth | 37.6 in |
| Height | 46.4 in |
| Width | 62.4 in |
| Internal Width | 33.5 in |
| Power Requirements | 115 volts, 60 Hz, 20 amps |
| Number of Glove Ports | 2 |
| Glove Box Construction | Stainless Steel |
| Glove Box Type | Stand Alone |
| Ducting | Ductless |
| Additional Model Specifications | [u]Protector Stainless Steel Combination Glove Box with Pressure Control Module, Auto Purge/Fill Sequencer and Foot Pedal[/u]
Filter Type: HEPA Primary Application: Work with both atmosphere-sensitive and/or hazardous materials Electrical Requirements: Domestic Power Cord & Plug: 115 volts, 20 amps Required Accessories: supporting base Built-In Options: Pressure control module, foot pedal and purge/fill control module Interior-mounted electrical outlets: 115 volt, 6 amp maximum combined rating Exterior back mounted electrical outlet: 115 volt, 9 amp NOTE: Also available with "International Electrical Requirements" |