Yamato Scientific America - RE300/600/800
Manufactured by Yamato Scientific America
Rotary Evaporator RE300/600/800
The rotary evaporator is compact, which can be neatly installed in a fume hood. Despite its depth of 400 mm, the vertical condenser (Glassware B/C) does not take up space.
Active Questions & AnswersAsk a Question
There are no current Discussions
Rotary Service ProvidersView All (9)
Documents & Manuals
There are no Documents or Manuals available.
Features of RE300/600/800
- Motorized lift standard for all models
- Digital settings and display in Japanese or English
- Space-saving design
- Movable rotary joint
- Quick release of evaporating flask
- Newly designed glass components (Guard against liquid stagnation)
- Water bath (oil bath)
- Voltage-sensing power pack
- Hose joints
General Specifications
There are no General Specifications available.
Series Modals
Yamato Scientific America - RE300
[+] View Model SpecificationsDepth | 400 mm With Glassware A |
Height | 580 mm With Glassware A |
Evaporator Orientation | Diagonal |
Width | 828 mm With Glassware A |
Power Requirements | 100 - 240V AC, 1.5A |
Lift Height | 150 mm |
Lift Handle | Motor |
Weight | 13 kg (excluding the glassware and the water/oil bath) |
Evaporator Type | Rotary |
Additional Model Specifications | Motor: DC brushless motor (for rotation) and DC motor (for lifting) Speed (rpm) setting: Control knob (digital indication) Safety measures (main unit): Manual-setting lower limit, upper limit, motor overload Lifting feature: Motorized lifting system External Dimension With Glassware B/C (mm): 643(W)× 400(D)×717(H)(877(H)when raised) |
Yamato Scientific America - RE600
[+] View Model SpecificationsDepth | 400 mm With Glassware A |
Height | 721 mm With Glassware A |
Evaporator Orientation | Diagonal |
Width | 828 mm With Glassware A |
Power Requirements | 100 - 240V AC, 1.5A |
Lift Height | 150 mm |
Lift Handle | Motor |
Weight | 14 kg (excluding the glassware and the water/oil bath) |
Evaporator Type | Rotary |
Additional Model Specifications | Motor: DC brushless motor (for rotation) and DC motor (for lifting) Controller: Vacuum regulator VR600 Setting range of vacuum: 0-981hPa Measurable range of vacuum: 0-1033hPa Resolution of vacuum:1hPa Setting range of hysteresis: 1-50hPa Resolution of vapor temperature indicator: Selectable(either 1°C or 0.1°C) Readout of cooling water temperature: Depending on indicator(option) Resolution of cooling water temperature indicator: 1°C External Dimensions With Glassware B/C (mm): 643(W)× 400(D)×721(H)(881(H)when raised) |
Yamato Scientific America - RE800
[+] View Model SpecificationsDepth | 400 mm With Glassware A |
Height | 721 mm With Glassware A |
Evaporator Orientation | Diagonal |
Width | 828 mm With Glassware A |
Power Requirements | 100 - 240V AC, 1.5A |
Lift Height | 150 mm |
Lift Handle | Motor |
Weight | 14 kg (excluding the glassware and the water/oil bath) |
Evaporator Type | Rotary |
Additional Model Specifications | Motor: DC brushless motor (for rotation) and DC motor (for lifting) Controller: Vacuum regulator VR600 Motorized lift stroke: 150mm Setting range of vacuum: 0-981hPa Measurable range of vacuum: 0-1033hPa Resolution of vacuum:1hPa Setting range of hysteresis: 1-50hPa Resolution of vapor temperature indicator: Selectable(either 1°C or 0.1°C) Readout of cooling water temperature: Depending on indicator(option) Resolution of cooling water temperature indicator: 1°C External Dimensions With Glassware B/C (mm): 643(W)× 400(D)×721(H)(881(H)when raised) |