Environics - Series 2020 CEMCS

Manufactured by  Environics
Follow this Equipment

Continuous Emissions Monitoring Calibration System

The Environics® Series 2020 Continuous Emissions Monitoring Calibration System (CEMCS) automatically generates precise gas standards for rapid multi-point and multi-scale calibration of Continuous Emissions Monitors (CEM's). The Series 2020 precisely dilutes high concentration Protocol-1 or certified gas cylinders to an infinitely variable range of concentrations from high percents to low parts per million. The instrument meets or exceeds the performance requirements of the United States EPA 40 CFR Part 51 Method 205 Appendix M.      
      
The Series 2020 consists of a single chassis supporting up to six (6) mass flow controllers (standard configuration), a serpentine pre-mix zone and a zero dead-space final mixing zone. Gas wetted surfaces are Electropolished 316 stainless steel. Seals are gas-compatible elastomer. User interface includes a back-lit 80 character by 25 line cold-cathode liquid-crystal display and membrane keypad.      
      
The instrument's mass flow controllers are factory calibrated using a computer controlled primary flow standard traceable to the United States' National Institute of Standards and Technology (NIST). The calibration data consists of an eleven-point comparison of commanded versus actual flow with linear interpolation between the points.      
      
The Series 2020 is available in a standard 19 inch rack mountable configuration for station or van usage or a portable bench-top version.      
      
The optional RS-232 data interface permits remote or computer operation of the instrument.
Active Questions & AnswersAsk a Question

There are no current Discussions

Gas and Air Analyzers Service ProvidersView All (10)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of Series 2020 CEMCS
  • Broad range of dilution ratios (1:1 - 10,000:1, standard) allows the user to significantly reduce the number of gas cylinders needed to perform compliance tests.      
  • Broad dilution ratio capability allows calibration of most analyzer ranges from one cylinder of each gas, significantly reducing gas costs, transport and handling labor.      
  • Automatic calculation of dilution and span gas flows based on the concentration commanded by the user eliminates the need for manual computation and allows rapid transition from point to point and scale to scale.      
  • Internally-stored mass flow controller calibration data improves accuracy.      
  • High capacity memory permits storage and recall of up to 200 calibration "recipes", saving time and reducing errors.      
  • 25 line by 80 character display permits viewing of data in worksheet format.      
  • RS-232 Serial Data Interface permits remote operation and complete integration with a computer-controlled system.      
  • Automatically calculates K-factors using system gas library.
General Specifications
Depth 23.5 in
Height7 in
Width 17 in
Power Requirements 115 VAC (100 to 130 VAC), 50/60 Hz
Weight70 lbs (max.)
Additional Specifications

Performance(as a percent of setpoint)      
Accuracy:      
From 10 to 100% of Full Scale Flow      
Concentration: ± 1.0%      
Flow: ± 1.0%      
Repeatability: 0.05%      
Warm up time: 30 minutes      
      
Mechanical      
Gas connections: 1/4" Swagelok (or compatible fitting)      
      
Operating Pressures      
Minimum: 10 psig (0.67 Bar)      
Recommended: 25 psig (1.68 Bar)      
Maximum: 75 psig (5.04 Bar)      
      
Wetted Surfaces      
Tubing: Electropolished 316 Stainless Steel      
(Optional - Teflon, Hastelloy, Monel)      
MFC's: Stainless Steel (Optional - Hastelloy, Monel)      
Seals: Viton® (Optional - Kalrez®, Buna-N, Neoprene, Metal)      
      
Operating temperature: 32° - 122° F (0° - 50° C)      
Performance temperature: 59° - 95° F (15° - 35° C)