Air Science USA - Safefume™
Safefume™ Cyanoacrylate Fuming Chambers
The professionally designed automatic fuming chamber eliminates reliance on do-it yourself systems that lack user-safety allowances and microprocessor controls needed for repeatable results.
The Safefume™ system controls all functions from start-to-finish, permitting the investigator to initiate an unattended automatic cycle, establish the proper fuming intensity and duration, and to return upon completion to collect results.
Fuming time, humidity and chamber fume evacuation can be user-set to comply with internal department criteria, lab safety protocols or best practices in evidence management.
Active Questions & AnswersAsk a Question
There are no current Discussions
Forensic Lab Equipment Service ProvidersView All (4)
Documents & ManualsView All Documents
Features of Safefume™
Filter I.D. Window: A strategically placed front cover window shows the installed filter part number and installation date for convenience and to encourage timely filter replacement.
Filter Door Key: Filter access keys prevent unauthorized removal or accidental exposure to dirty filters.
Track & Wheel System: An efficient filter clamping mechanism allows removal of main filter(s) directly to disposal bag with track and wheel system.
Electrostatic Pre-Filter: The 99.5% effective electrostatic pre-filter protects and extends the life of the main filter and can be changed without tools while unit is running to prevent operator exposure to captured contaminants.
Dynamic Filtration Chamber: The dynamic filter chamber prevents leakage of contaminated air by maintaining partial vacuum in the filter plenum.
Control Panel: The microprocessor control panel manages the Printbuster™ Pro operating sequence with control, oversight and display of all processing functions. The LCD display works with a touchpad data entry keypad to establish all operating parameters.
Doors: Tempered glass, keyed doors with aluminum frame and tamper proof seal, provide improved security, stability and ease of cleaning. scratch-resistant glass (for lasting optimum visibility)
Fan: High velocity sparkless and brushless centrifugal fan.
Lighting: Vapor-proof fluorescent light.
Color: The cabinet is white with blue door(s).
Hanging Rods: Removable and adjustable stainless steel hanging rod for proper orientation of evidence.
Water Nebulizer/Humidifier: Water nebulizer to elevate humidity in chamber.
Hot Plate Accelerator: Hot plate to polymerize ethyl cyanoacrylate.
General Specifications
There are no General Specifications available.
Series Modals
Air Science USA - CA24S
[+] View Model SpecificationsAirflow (CFM) | 145 CFM |
Depth | 17.3 in |
Height | 24 in |
Internal Height | 12.8 in |
Width | 24 in |
Lighting | (2) 15 watts |
Noise Level | 50 dB 1 meter |
Weight | 156 lbs |
Construction | White polypropylene and epoxy coated steel |
Additional Model Specifications |
Air Science USA - CA30S
[+] View Model SpecificationsAirflow (CFM) | 145 CFM |
Depth | 28 in |
Height | 48 in |
Internal Height | 36 in |
Width | 30 in |
Lighting | (2) 15 watts |
Noise Level | 50 dB 1 meter |
Weight | 175 lbs |
Construction | White polypropylene and epoxy coated steel |
Additional Model Specifications |
Air Science USA - CA48S
[+] View Model SpecificationsAirflow (CFM) | 145 CFM |
Depth | 28 in |
Height | 48 in |
Internal Height | 36 in |
Width | 48 in |
Lighting | (2) 15 watts |
Noise Level | 50 dB 1 meter |
Weight | 306 lbs |
Construction | White polypropylene and epoxy coated steel |
Additional Model Specifications |
Air Science USA - CA60S
[+] View Model SpecificationsAirflow (CFM) | 145 CFM |
Depth | 28 in |
Height | 48 in |
Internal Height | 36 in |
Width | 60 in |
Lighting | (2) 15 watts |
Noise Level | 50 dB 1 meter |
Weight | 369 lbs |
Construction | White polypropylene and epoxy coated steel |
Additional Model Specifications |