Hitachi Medical Systems - L-2100 SMASH
Manufactured by Hitachi Medical Systems
The LaChrom Elite HPLC solvent delivery systems provide highly reproducible results over a wide range of flow rates.
The LaChrom Elite Solvent Delivery Modules provide precision, flexibility, and reliability for the most demanding HPLC applications.
The LaChrom Elite Solvent Delivery Modules deliver highly reproducible results over a wide range of flow rates. Compatible with both 1-mm micro-bore and high-throughput applications, as well as conventional columns, LaChrom Elite Pumps set new standards for flexibility, accuracy, and reliability in both isocratic and gradient modules of operation. As part of the LaChrom Elite HPLC system, these pumps are designed to meet your most stringent requirements, including government requirements for documentation and system suitability, while providing maximum up time and the lowest cost of ownership.
NOTE: Attributes are provided for the HIGH PRESSURE GRADIENT setting. Attributes for the LOW PRESSURE GRADIENT setting can be found in additional specifications.
The LaChrom Elite Solvent Delivery Modules deliver highly reproducible results over a wide range of flow rates. Compatible with both 1-mm micro-bore and high-throughput applications, as well as conventional columns, LaChrom Elite Pumps set new standards for flexibility, accuracy, and reliability in both isocratic and gradient modules of operation. As part of the LaChrom Elite HPLC system, these pumps are designed to meet your most stringent requirements, including government requirements for documentation and system suitability, while providing maximum up time and the lowest cost of ownership.
NOTE: Attributes are provided for the HIGH PRESSURE GRADIENT setting. Attributes for the LOW PRESSURE GRADIENT setting can be found in additional specifications.
Active Questions & AnswersAsk a Question
There are no current Discussions
Low Pressure Gradient Service ProvidersView All (21)
Documents & Manuals
There are no Documents or Manuals available.
Features of L-2100 SMASH
- Binary high-pressure mixing or quaternary low-pressure mixing modes of operation.
- Built-in time events allow contact closure of external devices such as column switching valves.
- High-resolution stepping motors and piston diameters matched to the flow rate allow the lowest mixing columns in high pressure mode.
General Specifications
Depth | 15.75 in |
Number of Solvents | 2 |
Height | 6 in |
Pump Max. Pressure | 5600 psi |
Width | 13.5 in |
Flow Precision | 0.1 % RSD or 0.02 min SD at 0.2 mL/min |
Flow Accuracy | 1 % (0.2 mL/min) |
Standard Flow Rate | 0.001 to 2.499 ml/min |
Weight | 24 lbs |
Additional Specifications
LOW PRESSURE GRADIENT
Flow rate range: 0.001 to 2.499 mL/min (0.2 to1.8 mL/min recommended)
Quaternary: Up to 4 eluents
Composition range: 0 to 100% (0.1% increments with CDS; 1% increments with front panel control)
Accuracy: +/- 1% (0.2 mL/min)
Precision: 0.1% RSD or 0.02 min SDat 0.2 mL/min