Lab Alliance - HPLC Autosampler
Manufactured by Lab Alliance
HPLC Autosampler with 1 uL – 5000 uL injection range.
These autosamplers provide outstanding performance and maximum flexibility in a variable-volume autosampler for UHP HPLC and LC-MS using state-of-the-art injection technology with fast injection and wash cycles. Efficient needle wash for low carry-over.
They are capable of handling well plates and sample vials, open or sealed. Thorough sample cooling is available as an option.
They are capable of handling well plates and sample vials, open or sealed. Thorough sample cooling is available as an option.
Active Questions & AnswersAsk a Question
There are no current Discussions
Autosamplers Service ProvidersView All (1)
Documents & ManualsView All Documents
Features of HPLC Autosampler
- Adds Flexibility and Capability
- Easy-To-Use Sample Prep
- State-Of-The-Art Injection Technology
- Modular Design for Easy Service
General Specifications
There are no General Specifications available.
Series Modals
Lab Alliance - SHLA84000
[+] View Model Specifications| Cross Contamination | 0.05 % (Uracil in water; with 300 µL wash) |
| Maximum Pressure | 10000 psi |
| Standard Injection Range | 1 to 5000 μL |
| Temperature Control | 0 |
| Additional Model Specifications | Sample loop: 100 uL loop (included)
Sample capacity: 2 well plates 96 or 384 (deep or shallow); 96 vials (1.5 ml); Option: 24 vials (10 ml) Injection precision: RSD for injection volume > 10 ΜL; [u]Full-loop:[/u] 0.3%; [u]Partial-loop:[/u] 0.5%; [u]ΜL-pick-up:[/u] 1.0% Needle wash: 1 solvent; programmable volume; wash reservoir: 250 ml Option: 6 wash solvents Cycle time: < 1 min, including 300 ΜL wash Injection Cycle Time: 10 to 15 seconds |
Lab Alliance - SHLA84001
[+] View Model Specifications| Cross Contamination | 0.05 % (Uracil in water; with 300 µL wash) |
| Maximum Pressure | 10000 psi |
| Temperature Range | 2 to 6 °C |
| Standard Injection Range | 1 to 5000 μL |
| Temperature Control | 1 |
| Additional Model Specifications | Sample loop: 100 uL loop (included)
Sample capacity: 2 well plates 96 or 384 (deep or shallow); 96 vials (1.5 ml); Option: 24 vials (10 ml) Injection precision: RSD for injection volume > 10 ΜL; [u]Full-loop:[/u] 0.3%; [u]Partial-loop:[/u] 0.5%; [u]ΜL-pick-up:[/u] 1.0% Needle wash: 1 solvent; programmable volume; wash reservoir: 250 ml Option: 6 wash solvents Cycle time: < 1 min, including 300 ΜL wash Injection Cycle Time: 10 to 15 seconds |
Lab Alliance - SHLA84010
[+] View Model Specifications| Cross Contamination | 0.05 % (Uracil in water; with 300 µL wash) |
| Maximum Pressure | 18000 psi |
| Standard Injection Range | 1 to 5000 μL |
| Temperature Control | 0 |
| Additional Model Specifications | Sample loop: 100 uL loop (included)
Sample capacity: 2 well plates 96 or 384 (deep or shallow); 96 vials (1.5 ml); Option: 24 vials (10 ml) Injection precision: RSD for injection volume > 10 ΜL; [u]Full-loop:[/u] 0.3%; [u]Partial-loop:[/u] 0.5%; [u]ΜL-pick-up:[/u] 1.0% Needle wash: 1 solvent; programmable volume; wash reservoir: 250 ml Option: 6 wash solvents Cycle time: < 1 min, including 300 ΜL wash Injection Cycle Time: 10 to 15 seconds |