7000 Series Triple Quadrupole GC/MS

The Agilent 7000B Quadrupole GC/MS/MS is the latest addition to Agilent’s MS portfolio. Scientists performing “target compound analysis” in SIM mode on complex samples will find many ways to use its increased selectivity and sensitivity. MS/MS reduces sample prep, shortens analysis cycles, eliminates false results, and simplifies data review for improved productivity. Based upon time-tested MSD components, the 7000B sets a higher standard for robust GC/MS/MS operation. The entire system and analysis process are supported by MassHunter software, which is designed to make MS analyses easier—from tuning to final report.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked byFC888

avatar placemark

Asked byJoy

GC-Tandem MS Service ProvidersView All (1)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of 7000 Series
  • High sensitivity EI source and ramped-iris for the detector improve sensitivity across the entire mass range (installation specification: S/N > 500:1 for 100 fg OFN)  
  • Industry leading MRM speed at 500 transitions per second with a minimum dwell time of 1 msec and zero cross-talk  
  • A high pressure, linear collision cell with “Helium Quench Gas” to reduce neutral noise from metastable helium atoms  
  • Proprietary hyperbolic quadrupole enhances performance up to 1050 u; the unique stability of the quartz monolith allows the analyzer to be heated to 200°C to eliminate contamination commonly seen with metal quadrupoles operated at lower temperatures  
  • High-performance chromatography provided by the Agilent 7890A GC  
  • Integrated Capillary Flow Technology provides reduced source maintenance, shorter analysis cycle times, and increased column lifetime  
  • Small laboratory bench footprint: the mass spectrometer is only 14 inches (35 cm) wide  
  • Inert ion source—programmable up to 350°C—delivers enhanced response for active compounds and late eluters  
  • Electron Impact (EI) and Chemical Ionization (PCI and NCI) sources available  
  • Triple-Axis HED-EM Detector provides lower neutral noise  
  • Differentially pumped vacuum system with a single mechanical roughing pump  
  • Productivity features such as Agilent Autotune, Batch-at-a-Glance data review, and parameter-less integrator  
  • Safe operation with hydrogen carrier gas
General Specifications
Mass Spectrometer TypeQuadrupole Mass Analyzer