Stratedigm - S1000Ex
The package is small. The performance isn't.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Flow Cytometers Service ProvidersView All (6)
Documents & ManualsView All Documents
Features of S1000Ex
Brilliant in more ways than one To see or not to see….that is the difference between high-end systems and many of the “low-cost” systems on the market today. In order to take the cost out of the product, many of these manufacturers will compromise by using inferior components or eliminating functionality that ensure 20/20 vision: resulting in a cytometer that cannot “read the fine print” in your sample. For routine applications with high antigen density, this may be fine. But in uncharted territory, how do you know what you are missing? Stratedigm has optimized the optical, fluidic and electronic elements to maximize the amount of light generated and collected from the sample, while minimizing the amount of background light that clouds the picture. And, we do it in a way that will not break your budget. The proof is in the data.
Continuous Availability Uptime is an important consideration in purchasing a cytometer and Stratedigm takes this very seriously—designing in quality and reliability from the get-go. Start with the optical bench— the patented single plate “unibody” construction is the underpinning of a rugged design that performs to-spec even if moved or jostled. The unique HDF assembly eliminates vibrational and temperature-related instability—and as an added bonus it reduces the product weight and number of parts required. Automated software routines for startup, shutdown and other tasks keep the instrument at-the-ready. And, continuous software monitoring of key variables alert you when attention is needed…before it becomes a problem. Our Stratemanager™ Remote Diagnostics Agent can relay real-time service info and critical performance stats to our service center—improving service levels, uptime, and decreasing costs. The S1000Ex is ready when you are
Future-Proof Your Investment The Stratedigm S1000Ex is a future-proof investment - its integrated and modular-design ensures that the architecture is functionally open-ended and that upgrading is economically attractive. Given the diversity of applications, dyes, and labels available today, and the promise of even more tomorrow, the ability to customize your cytometer to your research needs is essential in today’s cost-constrained environment
General Specifications
There are no General Specifications available.
Additional Specifications
Detector Parameters/Data Acquisition
Forward Scatter (FSC) – Enables separation of unfixed platelets from noise
FSC resolution: 1Μm
FSC scales: Log & linear
FSC parameters: width, peak-height, area
Optional FSC photomulitiplier (PMT) detector
Side Scatter (SSC) – Resolves lympho-, mono- and granulocytes
SSC resolution: <.5Μm
SSC scales: log & linear
SSC parameters: width, peak-height, area
Fluorescence Detectors
Standard maximum number: 14, software assignable to different lasers
Sensitivity: <100 MESF
Fluorescence resolution: <2.5% CV
PMT scales: Log & linear
PMT parameters: width, peak-height, area
Time: 13Μsec resolution
User Interchangeable Optical Filters
Blue laser dyes: FITC (530/30), PE (580/30), PE-Texas Red (615/30), PerCP/PE-Cy5 (690/40), PE-Cy5.5 (710/40), PE-Cy7 (740LP)
Red laser dyes: APC (676/29), Alexa 700 (690/40), APCCy7 (740LP)
Green laser dyes: PE (580/30), PE-Texas Red/MCherry (615/30), PerCP/PE-Cy5 (690/40), PE-Cy5.5 (710/40), PE-Cy7 (740LP)
Violet laser dyes: Pacific Blue/DAPI (445/60), Pacific Orange/ AmCyan (540/40), QD 605 (615/30), QD 655 (676/29), QD 705 (690/40), QD 800 (740 LP)
Operating conditions: 5°-35°C
Tank capacity: 4L sheath, 4L waste, 4L auxiliary solution
Dead Volume: <8ΜL
Minimum sample size: <20Μ
Analysis rate: 10,000 events/sec
Carryover: <0.1%, automatic backflush between samples
Series Modals
Stratedigm - S1000Ex
[+] View Model SpecificationsDepth | 21 in (including fluidics tray) |
Height | 24 in (including fluidics tray) |
Width | 21.5 in (including fluidics tray) |
Power Requirements | 110 |
Weight | 70 lbs |
Additional Model Specifications | Detector Parameters/Data Acquisition Forward Scatter (FSC) – Enables separation of unfixed platelets from noise FSC resolution: 1Μm FSC scales: Log & linear FSC parameters: width, peak-height, area Optional FSC photomulitiplier (PMT) detector Side Scatter (SSC) – Resolves lympho-, mono- and granulocytes SSC resolution: <.5Μm SSC scales: log & linear SSC parameters: width, peak-height, area Fluorescence Detectors Standard maximum number: 14, software assignable to different lasers Sensitivity: <100 MESF Fluorescence resolution: <2.5% CV PMT scales: Log & linear PMT parameters: width, peak-height, area Time: 13Μsec resolution User Interchangeable Optical Filters Blue laser dyes: FITC (530/30), PE (580/30), PE-Texas Red (615/30), PerCP/PE-Cy5 (690/40), PE-Cy5.5 (710/40), PE-Cy7 (740LP) Red laser dyes: APC (676/29), Alexa 700 (690/40), APCCy7 (740LP) Green laser dyes: PE (580/30), PE-Texas Red/MCherry (615/30), PerCP/PE-Cy5 (690/40), PE-Cy5.5 (710/40), PE-Cy7 (740LP) Violet laser dyes: Pacific Blue/DAPI (445/60), Pacific Orange/ AmCyan (540/40), QD 605 (615/30), QD 655 (676/29), QD 705 (690/40), QD 800 (740 LP) Operating conditions: 5°-35°C Tank capacity: 4L sheath, 4L waste, 4L auxiliary solution Dead Volume: <8ΜL Minimum sample size: <20Μ Analysis rate: 10,000 events/sec Carryover: <0.1%, automatic backflush between samples |
Stratedigm - S1000EXi
[+] View Model SpecificationsDepth | 21 in (including fluidics tray) |
Height | 24 in (including fluidics tray) |
Width | 21.5 in (including fluidics tray) |
Power Requirements | 110 |
Weight | 70 lbs |
Additional Model Specifications | Detector Parameters/Data Acquisition Forward Scatter (FSC) – Enables separation of unfixed platelets from noise FSC resolution: <500nm FSC scales: Log & linear FSC parameters: width, peak-height, area Optional FSC photomulitiplier (PMT) detector Side Scatter (SSC) – Resolves lympho-, mono- and granulocytes SSC resolution: <200nm SSC scales: log & linear SSC parameters: width, peak-height, area Fluorescence Detectors Standard maximum number: 19, software assignable to different lasers Sensitivity: <40 MESF Fluorescence resolution: <2.5% CV PMT scales: Log & linear PMT parameters: width, peak-height, area Time: 13Μsec resolution User Interchangeable Optical Filters Detector Parameters/Data Acquisition Forward Scatter (FSC) – Enables separation of unfixed platelets from noise FSC resolution: 1Μm FSC scales: Log & linear FSC parameters: width, peak-height, area Optional FSC photomulitiplier (PMT) detector Side Scatter (SSC) – Resolves lympho-, mono- and granulocytes SSC resolution: <.5Μm SSC scales: log & linear SSC parameters: width, peak-height, area Fluorescence Detectors Standard maximum number: 14, software assignable to different lasers Sensitivity: <100 MESF Fluorescence resolution: <2.5% CV PMT scales: Log & linear PMT parameters: width, peak-height, area Time: 13Μsec resolution User Interchangeable Optical Filters Blue laser dyes: FITC (530/30), PE (580/30), PE-Texas Red (615/30),PerCP/PE-Cy5 (676/29), PE-Cy5.5 (690/40), PE-Cy7 (740LP) Red laser dyes: APC (676/29), APC-Cy5.5 (690/40), APC-Cy7 (740LP) Green laser dyes: PE (580/30), PE-Texas Red/MCherry (615/30), PerCP/PE-Cy5 (676/29), PE-Cy5.5 (690/40),PE-Cy7 (740LP) Violet laser dyes: Pacific Blue/DAPI(445/60), AmCyan (530/30), Pacific Orange (580/30), QD 605 (615/30), QD655 (676/29), QD 705 (710/40), QD 800 (740 LP) Operating conditions: 60–86° F (15–30°C) Tank capacity: 4L sheath, 4L waste, 4L auxiliary solution Dead Volume: <8ΜL Minimum sample size: <20ΜL Analysis rate: 10,000 events/sec Carryover: <0.1%, automatic backflush between samples |