GE Analytical Instruments - Sievers 500 RL

Manufactured by  GE Analytical Instruments
Follow this Equipment

Continuous Online Monitoring of TOC

The Sievers 500 RL On-Line Total Organic Carbon (TOC) Analyzer is a reagentless analyzer designed to continuously monitor organics in ultrapure water for pharmaceutical, microelectronics, semiconductor, and power applications. The Sievers 500 RL On-Line TOC Analyzer provides the superior analytical accuracy and performance found in all Sievers TOC Analyzers, with a 0.03 ppb limit of detection and autozero capabilities for unsurpassed low-level performance. The 500 RL TOC Analyzer provides a range of options, including the innovative 4-port Super iOS standards introduction device, that can be customized to meet the specific needs of a wide variety of applications.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked bysedki157832

avatar placemark

Updated byLabX Staff

TOC Analyzers Service ProvidersView All (11)

Request Support
Features

There are no Features available.

General Specifications
Depth 10.8 in
Measurement Range0.03 to 2500 ppb
On-Line Monitoring1
Height16.5 in
Width 19 in
NDIR0
Power Requirements 100–240 ±10% VAC, 50/60 Hz
Peak Power50 W
Weight37.2 lbs
Portable0
Additional Specifications

Total Organic Carbon  
Measurement Range: 0.03 to 2500 ppb  
Accuracy: ± 5% of measurement  
Precision: < 1% RSD or 0.03 ppb as C, whichever is greater  
pH Range: 5.5 to 8.0 in order to meet accuracy specification  
Analysis Modes: On-Line, On-Line Averaged, On-Line Timed  
Analysis Time: Continuous mode: 6 minutes  
Average and timed modes: 0.5, 1, 4, 8, or 24 hours  
Ozone Compatibility3: Maximum 200 ppb as O3  
External Flow Rate: Minimum 50 mL/min  
Sample Temperature: 1° C to 95° C (34° F to 203° F)  
Sample Pressure: Up to 100 psig  
Interferences: Insensitive to organic heteroatoms  
Calibration Stability: Typically stable for 12 months  
Display Readout: 3 significant digits  
  
Conductivity  
Raw Conductivity Range4: 0.01 to 35 ΜS/cm  
Conductivity Accuracy3,4: ± 0.005 ΜS/cm or ± 1%, whichever is greater  
Conductivity Precision: < 0.25% RSD  
Maximum Sample Conductivity: 25 ΜS/cm at neutral pH  
  
Instrument  
Normal Operating Environment: Intended for indoor use only  
Ambient Temperature: 10° C to 40° C (50° F to 104° F)  
Maximum Relative Humidity: Up to 95%, noncondensing  
Maximum Altitude: 2,300 m (7,546 ft)  
Inputs: One isolated binary input  
Outputs: Three isolated 4-20mA outputs, one Serial (RS-232), one USB port,  
one parallel printer port, four alarm outputs, and one Ethernet port  
Installation/Overvoltage: Category II (protects against transients present in Category II power)  
Safety Certifications: ETL, CE  
Pollution Degree: 2 (normally only non-conductive pollution)  
Display: Backlit Quarter-VGA touchscreen display  
IP Rating: Environmental enclosure: IP 45