GE Analytical Instruments - Sievers 5310 C Portable
The Sievers 5310 C Portable Total Organic Carbon (TOC) Analyzer was designed specifically for the municipal drinking water market.
The Sievers 5310 C Portable TOC Analyzer, along with the Sievers 5310 C Laboratory and On-Line models, offer superior accuracy and precision across a dynamic operating range of 4 parts per billion (ppb) to 50 parts per million (ppm) TOC. The 5310 C TOC Analyzers were engineered for ease of use and cost-effective operation. They offer automated procedures such as calibration, verification, reagent adjustment, and percent removal calculation for easier, faster TOC monitoring. These low-maintenance Analyzers need no external reagents or gas supplies, and offer one-year calibration stability.
Active Questions & AnswersAsk a Question
Trouble with standarization
Recent Questions & Answers
Updated byLifeisBio
TOC Analyzers Service ProvidersView All (11)
Documents & ManualsView All Documents
Features of Sievers 5310 C Portable
Easy Operation — The 5310 C Analyzers’ large, color touch-screen display makes it easy to set up instrument parameters. No special training is required to operate the Analyzers.
Low Maintenance Requirements — The 5310 C Analyzers prompt users automatically to perform preventive maintenance—typically only a few hours per year. The modular design simplifies consumables replacement and preventive maintenance.
12-Month Calibration Stability — The 5310 C Analyzers offer 12-month calibration stability, unlike some analyzers that require weekly or even daily calibration. By following the on-screen prompts, users can select from various calibration routines.
General Specifications
Depth | 18.3 in |
Measurement Range | 4 to 50000 ppb |
Height | 14 in |
Width | 8.8 in |
NDIR | 0 |
Power Requirements | 100–240 ± 10% VAC, 50/60 Hz |
Peak Power | 50 W |
Weight | 27.5 lbs |
Measurement Time | 4 minutes |
Portable | 1 |
Additional Specifications
Operating Specifications
Measurement Range: 4 to 50000 ppb
Precision: < 1% RSD
Accuracy: ± 2% or ± 0.5 ppb, whichever is greater
Display Readout: 3 significant digits
Sample Type: On-line continuous, Autosampler, or discrete grab sample
Calibration: Typically stable for 12 months
Sample Temperature: 1–95 °C (34–203 °F)
Ambient Temperature: 10–40 °C (50–104 °F)
Instrument Sample Flow Rate: 0.5 mL/min
Instrument Specifications
Outputs: 4-20mA output (1); Serial (RS-232) output (2); USB port (1); parallel printer port (1); Ethernet
Display: Quarter-VGA, color touch-sensitive LCD
Safety Certifications: ETL, CE see Declaration of Conformity
Consumables
UV Lamp: 6 months
Acid Reagent: As needed, typically 6-12 months depending on usage
Oxidizer Reagent: As needed, typically 3-month stability; available in 150- or 300-mL cartridge
Pump Tubing: 12 months
Resin Bed: 12 months