ELGA - MEDICA Pro
Manufactured by ELGA
Single High Flow Purification System for Large or Multiple Clinical Diagnostic Analyzers
The MEDICA Pro supplies Clinical Laboratory Reagent Water (CLRW) standard (formally CLSI Type 1) water using UV and microfiltration technologies together with recirculation and ion exchange. This compact system is ideal to directly feed large or linked multiple analyzers
Active Questions & AnswersAsk a Question
2Replies
Cris, Sr Admin
1Replies
bad water quality
Water Purification Service ProvidersView All (6)
Documents & ManualsView All Documents
Features of MEDICA Pro
- Delivers up to 4 liters per minute of CLRW standard water (formally CLSI Type 1 water)
- Bacterial specification <1CFU/ml. Simple sanitization programme runs quickly
- Compatible with single and multiple clinical diagnostic analyzers which require up to 4 liters per minute of CLRW standard water
- Low running and consumable costs
- Space saving design with its integrated wrap around 50 liter reservoir
- A bypass loop for continual supply of compliant water in emergency situations to the analyzer
- Easy to install under a bench
- Full service and validation support
General Specifications
There are no General Specifications available.
Series Modals
ELGA - MEDICA Pro-120
[+] View Model SpecificationsDepth | 18.8 in |
Flow Rate | 9 L/min (requirement at 15°C) |
Height | 32.8 in (without casters) |
Width | 31.8 in |
Power Requirements | 230V ac, 50Hz, 115V, 60Hz |
Peak Power | 650 VA |
Water Purification Method | RO |
Weight | 110 kg (operational) |
ASTM Type | CLRW |
TOC | 30 ppb (max) |
Additional Model Specifications | Make-up rate @15°C: 120 l/hr Delivery flow rate – maximum: Up to 4 l/min @ 14psi (1bar) Inorganics (resistivity @25°C): >10 MΩ-cm Bacteria - typical: <1 CFU/ml Particles: 0.05 Μm filter Silica: <0.05 mg/l Feedwater Requirement Source: Tap water as detailed below Conductivity: <2000 ΜS/cm 3 Hardness: <250 ppm as CaCO3 Free Chlorine: <4 ppm Cl2 Chloramine: <1 ppm Cl2 Silica: <30 ppm SiO2 Fouling Index: <10 FI Iron/manganese: <0.1 ppm Organics: <3 ppm TOC Temperature: 4 – 40°C (Recommended 15 – 25°C) Drain requirements (gravity fall with air gap): 20 l/min Noise level: <63dBA |
ELGA - MEDICA Pro-30
[+] View Model SpecificationsDepth | 18.8 in |
Flow Rate | 9 L/min (requirement at 15°C) |
Height | 32.8 in (without casters) |
Width | 31.8 in |
Power Requirements | 230V ac, 50Hz, 115V, 60Hz |
Peak Power | 650 VA |
Water Purification Method | RO |
Weight | 102 kg (operational) |
ASTM Type | CLRW |
TOC | 30 ppb (max) |
Additional Model Specifications | Make-up rate @15°C: 30 l/hr Delivery flow rate – maximum: Up to 4 l/min @ 14psi (1bar) Inorganics (resistivity @25°C): >10 MΩ-cm Bacteria - typical: <1 CFU/ml Particles: 0.05 Μm filter Silica: <0.05 mg/l Feedwater Requirement Source: Tap water as detailed below Conductivity: <2000 ΜS/cm 3 Hardness: <250 ppm as CaCO3 Free Chlorine: <4 ppm Cl2 Chloramine: <1 ppm Cl2 Silica: <30 ppm SiO2 Fouling Index: <10 FI Iron/manganese: <0.1 ppm Organics: <3 ppm TOC Temperature: 4 – 40°C (Recommended 15 – 25°C) Drain requirements (gravity fall with air gap): 20 l/min Noise level: <63dBA |
ELGA - MEDICA Pro-60
[+] View Model SpecificationsDepth | 18.8 in |
Flow Rate | 9 L/min (requirement at 15°C) |
Height | 32.8 in (without casters) |
Width | 31.8 in |
Power Requirements | 230V ac, 50Hz, 115V, 60Hz |
Water Purification Method | RO |
Weight | 109 kg (operational) |
ASTM Type | CLRW |
TOC | 30 ppb (max) |
Additional Model Specifications | Make-up rate @15°C: 60 l/hr Delivery flow rate – maximum: Up to 4 l/min @ 14psi (1bar) Inorganics (resistivity @25°C): >10 MΩ-cm Bacteria - typical: <1 CFU/ml Particles: 0.05 Μm filter Silica: <0.05 mg/l Feedwater Requirement Source: Tap water as detailed below Conductivity: <2000 ΜS/cm 3 Hardness: <250 ppm as CaCO3 Free Chlorine: <4 ppm Cl2 Chloramine: <1 ppm Cl2 Silica: <30 ppm SiO2 Fouling Index: <10 FI Iron/manganese: <0.1 ppm Organics: <3 ppm TOC Temperature: 4 – 40°C (Recommended 15 – 25°C) Drain requirements (gravity fall with air gap): 20 l/min Noise level: <63dBA |